Product Details | CENTRIFUGAL FAN

4140-00-497-0686 A nonpositive displacement mechanical device having a centrifugal fan impeller inclosed within a housing. It is designed to move air or gas over a wide range of volumes and pressures. The air or gas is drawn in axially and discharged radially or drawn in radially and discharged axially by centrifugal force through an outlet in the housing.20216600062Aircraft Air Conditioning, Heating, and Pressurizing Equipment41400043Fans, Air Circulators, and Blower Equipment

Part Alternates: 771638, 879931, 4140-00-497-0686, 00-497-0686, 4140004970686, 004970686

Refrigeration, Air Conditioning, and Air Circulating Equipment | Fans, Air Circulators, and Blower Equipment

Supply Group (FSG) NSN Assign. NIIN
41 01 OCT 1969 00-497-0686

Drawings & Photos | NSN 4140-00-497-0686


Cross Reference | NSN 4140-00-497-0686

Part Number Cage Code Manufacturer
771638 19139 EASTMAN KODAK COMPANY DBA KODAK
879931 19139 EASTMAN KODAK COMPANY DBA KODAK

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 4140-00-497-0686

Technical Data | NSN 4140-00-497-0686

Characteristic Specifications
STYLE DESIGNATOR 56 FIXED, INVERTED, RECTANGULAR OUTLET
LENGTH 7.000 INCHES NOMINAL
OUTLET INSIDE WIDTH 2.875 INCHES NOMINAL
OUTLET INSIDE HEIGHT 2.875 INCHES NOMINAL
HEIGHT 7.500 INCHES NOMINAL
MATERIAL STEEL HOUSING
DRIVE TYPE DIRECT
PRIME MOVER TYPE ELECTRIC MOTOR
SPEED ADJUSTMENTS SINGLE SPEED
INCLOSURE TYPE PARTIALLY INCLOSED
AMBIENT TEMP AT FULL RATED POWER 85.0 DEG FAHRENHEIT
ELECTRICAL CONNECTION TYPE WIRE LEAD
OPERATING SPEED AT RATED CAPACITY IN RPM 2700.0
VOLTAGE IN VOLTS AND CURRENT TYPE 115.0 AC
PHASE SINGLE
AIR FLOW RATE 105.0 CUBIC FEET PER MINUTE NOMINAL
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE 0.8 INCHES OF WATER
STAGE QUANTITY 1
MOUNTING FACILITY TYPE AND QUANTITY 3 BOLT
OUTLET LOCATION TOP
MANUFACTURERS CODE 19139
DESIGN CONTROL REFERENCE 771638

Restrictions/Controls & Freight Information | NSN 4140-00-497-0686

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061920 FANS ELEC NOI IN BARREL/BOX/CRATE
Less than car load rating
Less than truck load rating J 100.2
Water commodity Code 752 unknown
Originating Activity Code SU Ogden Air Logistics Center
Hill AFB, UT 84056-5609
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable