Product Details | VENTILATING FAN

4140-01-006-5144 A nonpositive displacement mechanical device having either an axial or centrifugal fan impeller. It is designed to move free air or gas from indoors to outdoors or vice versa over a wide range of volumes at low pressures. It is supported by a ring, plate, or shroud or may be inclosed in a housing. It is designed for installation in a window, roof or wall opening, or the like.

Part Alternates: BS2107F30, BS2107F-30, 4710NL05WB30, 4710NL-05W-B30, 4140-01-006-5144, 01-006-5144, 4140010065144, 010065144

Refrigeration, Air Conditioning, and Air Circulating Equipment | Fans, Air Circulators, and Blower Equipment

Supply Group (FSG) NSN Assign. NIIN
41 18 JUL 1975 01-006-5144

Drawings & Photos | NSN 4140-01-006-5144


Demand History | NSN 4140-01-006-5144

Part Number Request Date QTY Origin
4140-01-006-5144 2011-03-67 2 US

Cross Reference | NSN 4140-01-006-5144

Part Number Cage Code Manufacturer
4710NL-05W-B30 6M191 BELL INDUSTRIES INC
BS2107F-30 18875 UNITED STATES CERAMIC TILE CO
BS2107F-30 6M191 BELL INDUSTRIES INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 4140-01-006-5144

Technical Data | NSN 4140-01-006-5144

Characteristic Specifications
STYLE DESIGNATOR 45 FIXED
WIDTH 4.688 INCHES NOMINAL
DIAMETER 4.688 INCHES MAXIMUM
LENGTH 1.500 INCHES NOMINAL
HEIGHT 4.688 INCHES NOMINAL
QUANTITY 1
MATERIAL STEEL BLADE STEEL HOUSING
DRIVE TYPE DIRECT
ROTATION DIRECTION FOR WHICH DESIGNED CLOCKWISE
PRIME MOVER TYPE ELECTRIC MOTOR
SPEED ADJUSTMENTS SINGLE SPEED
PRIME MOVER DRIVE SHAFT BEARING TYPE BALL
INCLOSURE TYPE GUARDED
VOLTAGE IN VOLTS AND CURRENT TYPE 28.0 DC
AIR FLOW RATE 120.0 CUBIC FEET PER MINUTE NOMINAL
FLOW DIRECTION REVERSIBLE
MOUNTING FACILITY TYPE AND QUANTITY 4 UNTHREADED HOLE
SPECIAL FEATURES CONTINUOUS OIL CIRCULATION

Restrictions/Controls & Freight Information | NSN 4140-01-006-5144

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061920 FANS ELEC NOI IN BARREL/BOX/CRATE
Less than car load rating
Less than truck load rating J 100.2
Water commodity Code 658 unknown
Originating Activity Code 28 NASA - Raytheon Service Company
Annapolis Junction, MD 20701-1116
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 4140-01-006-5144

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each