NSN 5905-00-134-0426 134FTS1074, 134FTS107-4, 220274
Product Details | NONPRECISION NONWIRE WOUND VARIABLE RESISTOR
5905-00-134-0426 A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The functional tolerance (linearity), if given, of the output is greater than plus or minus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. For items having manually positioned taps designed to be set and fixed prior to use, see RESISTOR, ADJUSTABLE. For items with step by step variation, see RHEOSTAT and RESISTOR, STEP BY STEP. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see ATTENUATOR, VARIABLE. Excludes RESISTOR (1), VARIABLE, WIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND PRECISION; and RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION.
Part Alternates: 134FTS1074, 134FTS107-4, 220274, 22027-4, 41219714, 412197-14, 5905-00-134-0426, 00-134-0426, 5905001340426, 001340426
Electrical and Electronic Equipment Components | Resistors
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 25 AUG 1969 | 00-134-0426 | 37405 ( RESISTOR, VARIABLE, NONWIRE WOUND, NONPRECISION ) |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5905-00-134-0426
Technical Data | NSN 5905-00-134-0426
| Characteristic | Specifications |
|---|---|
| SECTION QUANTITY | 2 |
| ELECTRICAL RESISTANCE PER SECTION | 8.5 KILOHMS 1ST SECTION 4.25 KILOHMS 2ND SECTION |
| RESISTANCE TOLERANCE PER SECTION IN PERCENT | -5.0 TO 5.0 ALL SECTIONS |
| STANDARD TAPER CURVE PER SECTION | A ALL SECTIONS |
| TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -300.0 TO 300.0 ALL SECTIONS |
| POWER DISSIPATION RATING PER SECTION IN WATTS | 4.0 FREE AIR ALL SECTIONS |
| AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 55.0 ALL SECTIONS |
| AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 85.0 ALL SECTIONS |
| FIXED TAP QUANTITY PER SECTION | 1 1ST SECTION |
| TAP LOCATION FROM CCW TERMINAL PER SECTION IN OHMS | 4250.0 1ST SECTION |
| TAP LOCATION TOLERANCE PER SECTION | -1.0 TO 1.0 OHMS 1ST SECTION |
| BODY STYLE | 5B CYLINDRICAL SERVO MOUNTED |
| PILOT DIAMETER | 1.5620 INCHES MAXIMUM |
| PILOT LENGTH | 0.0620 INCHES NOMINAL |
| UNDERCUT DIAMETER | 1.750 INCHES MAXIMUM |
| UNDERCUT WIDTH | 0.0780 INCHES NOMINAL |
| BODY DIAMETER | 1.767 INCHES MAXIMUM |
| BODY LENGTH | 0.977 INCHES MAXIMUM |
| MOUNTING LIP DIAMETER | 1.7670 INCHES MAXIMUM |
| MOUNTING LIP DEPTH | 0.0930 INCHES NOMINAL |
| ACTUATOR TYPE | SINGLE SHAFT |
| SHAFT STYLE | 1C ROUND |
| SHAFT DIAMETER | 0.125 INCHES NOMINAL |
| SHAFT LENGTH | 0.562 INCHES NOMINAL |
| CONTACT ARM ELECTRICAL OFF POSITION | FULLY CCW-CW |
| ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 360.0 NOMINAL |
| ACTUATOR TRAVEL CONTROL FEATURE | CONTINUOUS MOTION |
| EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 165.0 MINIMUM AND 175.0 MAXIMUM |
| MOUNTING METHOD | CLAMP RING |
| FEATURES PROVIDED | NONMETALLIC SHAFT |
| TERMINAL TYPE AND QUANTITY | 7 TAB, SOLDER LUG |
| TERMINAL LOCATION | RADIALLY POSITIONED OVER LESS THAN HALF THE CIRCUMFERENCE |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| TEST DATA DOCUMENT | 80020-41297 DRAWING |
| III OVERALL LENGTH | 2.230 INCHES MAXIMUM |
| III OVERALL DIAMETER | 2.120 INCHES MAXIMUM |
Restrictions/Controls & Freight Information | NSN 5905-00-134-0426
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Electro-static Discharge Susceptible: | B | ESD sensitivity |
| Precious Metals Indicator Code: | U | Precious metal type is unknown |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 062960 | REOSTATS/PARTS NOI |
| Less than car load rating | ||
| Less than truck load rating | P | 77.5 |
| Water commodity Code | 72D | unknown |
| Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | 3 | Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices). |
Management | NSN 5905-00-134-0426
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |