Product Details | NONPRECISION NONWIRE WOUND VARIABLE RESISTOR

5905-00-904-6707 A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The functional tolerance (linearity), if given, of the output is greater than plus or minus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. For items having manually positioned taps designed to be set and fixed prior to use, see RESISTOR, ADJUSTABLE. For items with step by step variation, see RHEOSTAT and RESISTOR, STEP BY STEP. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see ATTENUATOR, VARIABLE. Excludes RESISTOR (1), VARIABLE, WIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND PRECISION; and RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION.

Part Alternates: MIL-R-22097/1, MILR220971, RJ11AS254, 3809164000, 380-9164-000, 5905-00-904-6707, 00-904-6707, 5905009046707, 009046707

Electrical and Electronic Equipment Components | Resistors

Supply Group (FSG) NSN Assign. NIIN
59 20 JUN 1966 00-904-6707

Drawings & Photos | NSN 5905-00-904-6707


Cross Reference | NSN 5905-00-904-6707

Part Number Cage Code Manufacturer
380-9164-000 13499 ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS
MIL-R-22097/1 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
RJ11AS254 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5905-00-904-6707

Technical Data | NSN 5905-00-904-6707

Characteristic Specifications
SECTION QUANTITY 1
ELECTRICAL RESISTANCE PER SECTION 250.0 KILOHMS SINGLE SECTION
RESISTANCE TOLERANCE PER SECTION IN PERCENT -10.0 TO 10.0 SINGLE SECTION
STANDARD TAPER CURVE PER SECTION A SINGLE SECTION
MAXIMUM STARTING TORQUE 8.00 INCH-OUNCES
RESISTANCE TEMP CHARACTERISTIC RANGE PER SECTION IN PERCENT 0.0 TO 8.0 -55 DEG CELSIUS SINGLE SECTION AND 0.0 TO 4.0 -25 DEG CELSIUS SINGLE SECTION AND -0.0 TO 0.0 25 DEG CELSIUS SINGLE SECTION AND -3.0 TO 3.0 85 DEG CELSIUS SINGLE SECTION AND -6.5 TO 6.5 125 DEG CELSIUS SINGLE SECTION
POWER DISSIPATION RATING PER SECTION IN WATTS 0.25 FREE AIR SINGLE SECTION
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER 70.0 SINGLE SECTION
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER 125.0 SINGLE SECTION
BODY STYLE 26B RECTANGULAR W/MOUNTING HOLES/SLOTS
BODY LENGTH 1.218 INCHES MINIMUM AND 1.282 INCHES MAXIMUM
BODY WIDTH 0.235 INCHES MINIMUM AND 0.300 INCHES MAXIMUM
BODY HEIGHT 0.275 INCHES NOMINAL
LATERAL DISTANCE BETWEEN MOUNTING HOLE CENTERS 0.109 INCHES MINIMUM AND 0.160 INCHES MAXIMUM
ACTUATOR TYPE SINGLE SHAFT
SHAFT STYLE 3C ROUND, SLOTTED
SHAFT DIAMETER 0.100 INCHES MINIMUM AND 0.140 INCHES MAXIMUM
SHAFT LENGTH 0.036 INCHES MINIMUM AND 0.077 INCHES MAXIMUM
ROTARY ACTUATOR TRAVEL IN ANGULAR DEG 6120.0 MINIMUM AND 9720.0 MAXIMUM
ACTUATOR TRAVEL CONTROL FEATURE CLUTCH
EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION 6120.0 MINIMUM AND 9720.0 MAXIMUM
MOUNTING METHOD UNTHREADED HOLE
MOUNTING FACILITY QUANTITY 2
MOUNTING HOLE DIAMETER 0.088 INCHES MINIMUM AND 0.098 INCHES MAXIMUM
TERMINAL TYPE AND QUANTITY 3 TAB, SOLDER LUG
CENTER TO CENTER DISTANCE BETWEEN TERMINALS 0.490 INCHES MINIMUM AND 0.510 INCHES MAXIMUM
TERMINAL LENGTH 0.110 INCHES MINIMUM AND 0.234 INCHES MAXIMUM
TERMINAL LOCATION LOWER ADJACENT SIDE SINGLE ROW
CENTER TO CENTER DISTANCE BETWEEN TERMINAL ROWS 0.100 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED
TEST DATA DOCUMENT 81349-MIL-R-22097 SPECIFICATION
SPECIFICATION/STANDARD DATA 81349-MIL-R-22097/1 GOVERNMENT SPECIFICATION

Restrictions/Controls & Freight Information | NSN 5905-00-904-6707

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:BESD sensitivity
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 062960 REOSTATS/PARTS NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo 3 Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

Management | NSN 5905-00-904-6707

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each