Product Details | ELECTROLYTIC FIXED CAPACITOR

5910-00-006-5338 A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Part Alternates: TIM104K035P0X, 5910-00-006-5338, 00-006-5338, 5910000065338, 000065338

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 00-006-5338

Drawings & Photos | NSN 5910-00-006-5338


Cross Reference | NSN 5910-00-006-5338

Part Number Cage Code Manufacturer
10275422-1 18876 U S ARMY AVIATION AND MISSILE COMMAND
KR1P50K 31433 KEMET ELECTRONICS CORPORATION DBA KEMET
T330B104K050AS 05397 UNION CARBIDE CORP MATERIALS SYSTEMS DIV
TIM104K035P0X 00853 CORNELL-DUBILIER MARKETING, INC.
TIM104K035P0X 90201 MALLORY SONALERT PRODUCTS INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-00-006-5338

Technical Data | NSN 5910-00-006-5338

Characteristic Specifications
CAPACITANCE VALUE PER SECTION 0.100 MICROFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION -10.00 TO 10.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 35.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
BODY STYLE 27A W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
BODY LENGTH 0.285 INCHES NOMINAL
BODY WIDTH 0.225 INCHES NOMINAL
BODY HEIGHT 0.170 INCHES NOMINAL
SCHEMATIC DIAGRAM DESIGNATOR 1C NO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL TYPE AND QUANTITY 2 UNINSULATED WIRE LEAD
TERMINAL LENGTH 1.500 INCHES MINIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.195 INCHES MINIMUM AND 0.205 INCHES MAXIMUM
CASE MATERIAL PLASTIC
CAPACITIVE ELECTRODE MATERIAL TANTALUM
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT 4.0000
DC LEAKAGE AT REFERENCE TEMP 0.500 MICROAMPERES
ELECTRICAL POLARIZATION POLARIZED
RELIABILITY INDICATOR NOT ESTABLISHED
III TERMINAL SURFACE TREATMENT SOLDER
III ANODE TYPE SOLID
III DC LEAKAGE AT MAXIMUM OPERATING TEMP 6.25 MILLIAMPERES

Restrictions/Controls & Freight Information | NSN 5910-00-006-5338

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Category Code Description
No Freight Information