Product Details | ELECTROLYTIC FIXED CAPACITOR

5910-00-007-3975 A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Part Alternates: M39003/01-2288, M39003/01-3008, M39003012288, M39003012768, M39003-01-2768, M39003013008, SCM126BP020D2, CS13BE126K, T110B126K010AS, TAS126K020P1C, MIL-C-39003/1, MILC390031, 1060653621, 10606536-21, 150D126X9020B0, 192815, 200325-288, 201161-120, 352250018915, 9011269WB3, 5910-00-007-3975, 00-007-3975, 5910000073975, 000073975, 201161120, 200325288

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 06 JUL 1972 00-007-3975

Drawings & Photos | NSN 5910-00-007-3975


Cross Reference | NSN 5910-00-007-3975

Part Number Cage Code Manufacturer
10606536-21 18876 U S ARMY AVIATION AND MISSILE COMMAND
150D126X9020B0 56289 SPRAGUE ELECTRIC CO WORLD HQS
200325-288 81413 BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION I
201161-120 32274 CIPHER DATA PRODUCTS INC OEM MARKETING DIV
352250018915 H0203 THALES NEDERLAND B.V. DBA THALES LAND & JOINT SYSTEMS
9011269WB3 84411 AMERICAN SHIZUKI CORPORATION
CS13BE126K 56289 SPRAGUE ELECTRIC CO WORLD HQS
M39003-01-2768 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M39003/01-2288 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M39003/01-3008 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MIL-C-39003/1 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
SCM126BP020D2 01295 TEXAS INSTRUMENTS INCORPORATED DBA TEXAS INSTRUMENTS
SCM126BP020D2 96214 RAYTHEON COMPANY DBA RAYTHEON
T110B126K010AS 31433 KEMET ELECTRONICS CORPORATION DBA KEMET
TAS126K020P1C 90201 MALLORY SONALERT PRODUCTS INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-00-007-3975

Technical Data | NSN 5910-00-007-3975

Characteristic Specifications
CAPACITANCE VALUE PER SECTION 12.000 MICROFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION -10.00 TO 10.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 20.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
BODY STYLE 26B W/O MTG FACILITIES, AXIAL TERMINALS
BODY DIAMETER 0.185 INCHES NOMINAL
BODY LENGTH 0.474 INCHES NOMINAL
SCHEMATIC DIAGRAM DESIGNATOR 3C ELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL
TERMINAL TYPE AND QUANTITY 2 UNINSULATED WIRE LEAD
TERMINAL LENGTH 1.500 INCHES NOMINAL
TERMINAL DIAMETER 0.020 INCHES NOMINAL
CASE MATERIAL METAL
CASE INSULATION MATERIAL PLASTIC
CAPACITIVE ELECTRODE MATERIAL TANTALUM
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT 6.000
DC LEAKAGE AT REFERENCE TEMP 3.500 MICROAMPERES
ELECTRICAL POLARIZATION POLARIZED
RELIABILITY INDICATOR ESTABLISHED
RELIABILITY FAILURE RATE LEVEL IN PERCENT 0.001
FEATURES PROVIDED HERMETICALLY SEALED CASE
SPECIAL FEATURES WEIBULL GRADED FAILURE RATE
TEST DATA DOCUMENT 81349-MIL-C-39003 SPECIFICATION
SPECIFICATION/STANDARD DATA 81349-MIL-C-39003/1 GOVERNMENT SPECIFICATION
CRITICALITY CODE JUSTIFICATION FEAT
III MIL-STD-1276 WIRE LEAD TYPE DESIGNATOR N-3
III ANODE TYPE SOLID
(NON-CORE DATA) OVERALL LENGTH 0.610 INCHES MAXIMUM
III DC LEAKAGE AT MAXIMUM OPERATING TEMP 35.0 MICROAMPERES
(NON-CORE DATA) OVERALL HEIGHT 0.185 INCHES NOMINAL
(NON-CORE DATA) OVERALL WIDTH 0.185 INCHES NOMINAL
MANUFACTURERS CODE 81349
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE MIL-C-39003/1
MANUFACTURERS CODE 81349
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE M39003/01-3008

Restrictions/Controls & Freight Information | NSN 5910-00-007-3975

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:YThe item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 116250 TYPEWRITERS/TELETYPEWRITERS/PARTS
Less than car load rating
Less than truck load rating J 100.2
Water commodity Code 734 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5910-00-007-3975

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative