NSN 5910-00-542-7387 C605000597, C605000643, S30-9
Product Details | ELECTROLYTIC FIXED CAPACITOR
5910-00-542-7387 A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.
Part Alternates: C605000597, C605000643, S30-9, SMB336898272, T110B475M035AU, U208E702X145, W4913247P9, K4R7J35, S309, 037083, 037-083, 150D475X0035B2, 1847396000, 184-7396-000, 290-0187-00, 4431001, 475X0035B2, 632384-272, 8617394, 912016, 91201-6, 5910-00-542-7387, 00-542-7387, 5910005427387, 290018700, 005427387, 632384272
Electrical and Electronic Equipment Components | Capacitors
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 01 JAN 1963 | 00-542-7387 | 00008 ( CAPACITOR, FIXED, ELECTROLYTIC ) |
Demand History | NSN 5910-00-542-7387
| Part Number | Request Date | QTY | Origin |
|---|---|---|---|
| S309 | 2011-01-16 | 10 |
Cross Reference | NSN 5910-00-542-7387
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 037-083 | 92739 | AMPEX SYSTEMS CORP |
| 150D475X0035B2 | 56289 | SPRAGUE ELECTRIC CO WORLD HQS |
| 184-7396-000 | 13499 | ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS |
| 290-0187-00 | 80009 | TEKTRONIX, INC. DBA TEKTRONIX |
| 4431001 | N0086 | KONGSBERG DEFENCE & AEROSPACE AS |
| 475X0035B2 | 56289 | SPRAGUE ELECTRIC CO WORLD HQS |
| 632384-272 | 56232 | LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN |
| 632384272 | 56232 | LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN |
| 8617394 | 10001 | NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT |
| 8617394 | 19204 | ARMY UNITED STATES DEPARTMENT OF THE |
| 91201-6 | 04643 | COMTEC INFORMATION SYSTEMS INC DIGITRONICS DIV |
| C605000597 | 93236 | DRESSER-RAND CO WORTHINGTON COMPRESSOR OPN |
| C605000643 | 88818 | KEARFOTT CORPORATION DBA KEARFOTT |
| K4R7J35 | 05397 | UNION CARBIDE CORP MATERIALS SYSTEMS DIV |
| S30-9 | 48294 | PSI-PERIPHERAL SUPPORT |
| S30-9 | 54418 | MILTOPE CORPORATION |
| SMB336898272 | 80063 | US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS |
| T110B475M035AU | 05397 | UNION CARBIDE CORP MATERIALS SYSTEMS DIV |
| U208E702X145 | S3120 | SIEMENS SCHWEIZ AG DBA SIEMENS SWITZERLAND LTD. |
| W4913247P9 | S3092 | RHEINMETALL AIR DEFENCE AG |
| W4913247P9 | S3118 | OERLIKON-BUEHRLE AG WERKZEUGMASCHINENFABRIK |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5910-00-542-7387
Related Products | NSN 5910-00-542-7387
Technical Data | NSN 5910-00-542-7387
| Characteristic | Specifications |
|---|---|
| CAPACITANCE VALUE PER SECTION | 4.700 MICROFARADS SINGLE SECTION |
| TOLERANCE RANGE PER SECTION | -20.00 TO 20.00 PERCENT SINGLE SECTION |
| NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 35.0 DC SINGLE SECTION |
| NONDERATED OPERATING TEMP | -80.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
| BODY STYLE | 26B W/O MTG FACILITIES, AXIAL TERMINALS |
| BODY DIAMETER | 0.185 INCHES NOMINAL |
| BODY LENGTH | 610.000 INCHES MAXIMUM |
| SCHEMATIC DIAGRAM DESIGNATOR | 3C ELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL |
| TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
| TERMINAL LENGTH | 1.500 INCHES NOMINAL |
| CASE MATERIAL | METAL |
| CASE INSULATION MATERIAL | PLASTIC |
| CAPACITIVE ELECTRODE MATERIAL | TANTALUM |
| DC LEAKAGE AT REFERENCE TEMP | 5.000 MICROAMPERES |
| ELECTRICAL POLARIZATION | POLARIZED |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| FEATURES PROVIDED | HERMETICALLY SEALED CASE |
| III TERMINAL SURFACE TREATMENT | SOLDER |
| III ANODE TYPE | SOLID |
| III IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS | 0.03 |
| (NON-CORE DATA) OVERALL LENGTH | 0.642 INCHES MINIMUM |
| (NON-CORE DATA) OVERALL HEIGHT | 0.185 INCHES NOMINAL |
| (NON-CORE DATA) OVERALL WIDTH | 0.185 INCHES NOMINAL |
Restrictions/Controls & Freight Information | NSN 5910-00-542-7387
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 061400 | CONDENSERS/PARTS NOI/CAPACITORS |
| Less than car load rating | ||
| Less than truck load rating | P | 77.5 |
| Water commodity Code | 658 | unknown |
| Originating Activity Code | XX | |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5910-00-542-7387
| Category | Code | Description |
|---|---|---|
| Stores Account Code | 1 | Marine Corps Stock Fund Account Item. |
| Combat Essentiality Code | 5 | Critical Repair Part to a Combat Essential End Item. Those parts or components whose failure in a combat essential end item will render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency. |
| Materiel Management Code | E | Electronics MaterielDefense Electronics Supply Center (DESC) |
| Echelon Management Code | 2 | ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled. |
| Source of Supply | S9E | Defense Supply Center Columbus Columbus, OH 43218 |
| Agency | DM | U.S. Marine Corps |
| Service Organization | M | U.S. Marine Corps |
| Reparability | Z | Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code. |
| Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9N | Navy-owned stocks of defense electronic material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | S9E | Defense Supply Center Columbus Columbus, OH 43218 |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |