Product Details | ELECTROLYTIC FIXED CAPACITOR

5910-00-879-2904 A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Part Alternates: 150D334X9015A2, 5910-00-879-2904, 00-879-2904, 5910008792904, 008792904

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1962 00-879-2904

Drawings & Photos | NSN 5910-00-879-2904


Cross Reference | NSN 5910-00-879-2904

Part Number Cage Code Manufacturer
150D334X9015A2 56289 SPRAGUE ELECTRIC CO WORLD HQS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-00-879-2904

Technical Data | NSN 5910-00-879-2904

Characteristic Specifications
CAPACITANCE VALUE PER SECTION 0.330 MICROFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION -10.00 TO 10.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 15.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP -80.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
BODY STYLE 26B W/O MTG FACILITIES, AXIAL TERMINALS
BODY DIAMETER 0.125 INCHES NOMINAL
BODY LENGTH 0.250 INCHES NOMINAL
SCHEMATIC DIAGRAM DESIGNATOR 3C ELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL
TERMINAL TYPE AND QUANTITY 2 UNINSULATED WIRE LEAD
TERMINAL LENGTH 1.500 INCHES NOMINAL
CASE MATERIAL METAL
CASE INSULATION MATERIAL PLASTIC
CAPACITIVE ELECTRODE MATERIAL TANTALUM
DC LEAKAGE AT REFERENCE TEMP 0.600 MICROAMPERES
ELECTRICAL POLARIZATION POLARIZED
RELIABILITY INDICATOR NOT ESTABLISHED
FEATURES PROVIDED HERMETICALLY SEALED CASE
III TERMINAL SURFACE TREATMENT SOLDER
(NON-CORE DATA) OVERALL LENGTH 0.286 INCHES NOMINAL
(NON-CORE DATA) OVERALL HEIGHT 0.135 INCHES NOMINAL
(NON-CORE DATA) OVERALL WIDTH 0.135 INCHES NOMINAL

Restrictions/Controls & Freight Information | NSN 5910-00-879-2904

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information