Product Details | ELECTROLYTIC FIXED CAPACITOR

5910-01-120-1875 A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Part Alternates: CDEUHA10070 , 0067592, 006759-2, 5910-01-120-1875, 01-120-1875, 5910011201875, 011201875

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 12 OCT 1981 01-120-1875

Drawings & Photos | NSN 5910-01-120-1875


Cross Reference | NSN 5910-01-120-1875

Part Number Cage Code Manufacturer
006759-2 058R3 GE AVIATION SYSTEMS LLC DIV CUSTOMER SERVICES
006759-2 19623 GE AVIATION SYSTEMS LLC DBA GE AVIATION
CDEUHA10070 00853 CORNELL-DUBILIER MARKETING, INC.
CDEUHA10070 14655 CORNELL-DUBILIER ELECTRONICS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-01-120-1875

Technical Data | NSN 5910-01-120-1875

Characteristic Specifications
CAPACITANCE VALUE PER SECTION 1300.000 MICROFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION -10.00 TO 50.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 60.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 105.0 DEG CELSIUS MAXIMUM
BODY STYLE 26B W/O MTG FACILITIES, AXIAL TERMINALS
BODY DIAMETER 1.035 INCHES MAXIMUM
BODY LENGTH 3.687 INCHES MAXIMUM
SCHEMATIC DIAGRAM DESIGNATOR 1C NO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL TYPE AND QUANTITY 2 UNINSULATED WIRE LEAD
TERMINAL LENGTH 2.250 INCHES MINIMUM AND 2.750 INCHES MAXIMUM
TERMINAL DIAMETER 0.040 INCHES NOMINAL
CASE MATERIAL METAL
CASE INSULATION MATERIAL PLASTIC
CAPACITIVE ELECTRODE MATERIAL ALUMINUM
EQUIVALENT SERIES RESISTANCE AT REFERENCE TEMP IN OHMS 0.10
DC LEAKAGE AT REFERENCE TEMP 130.000 MICROAMPERES
ELECTRICAL POLARIZATION POLARIZED
RELIABILITY INDICATOR NOT ESTABLISHED
III TERMINAL SURFACE TREATMENT SOLDER
III ANODE TYPE ETCHED FOIL
III IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS 3.5
(NON-CORE DATA) OVERALL LENGTH 3.687 INCHES MAXIMUM
III DC LEAKAGE AT MAXIMUM OPERATING TEMP 800.0 MICROAMPERES
(NON-CORE DATA) OVERALL HEIGHT 1.035 INCHES MAXIMUM
(NON-CORE DATA) OVERALL WIDTH 1.035 INCHES MAXIMUM
MANUFACTURERS CODE 058R3
MFR SOURCE CONTROLLING REFERENCE 006759-2

Restrictions/Controls & Freight Information | NSN 5910-01-120-1875

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061400 CONDENSERS/PARTS NOI/CAPACITORS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code SX Oklahoma City Air Logistics Center
Tinker AFB, OK 73145-3043
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5910-01-120-1875

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeFGSX:B-52 STRATO FORTRESS
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each