NSN 5910-01-177-9063 H475M035, DL15193106, DMS91057B
Product Details | ELECTROLYTIC FIXED CAPACITOR
5910-01-177-9063 A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.
Part Alternates: H475M035, DL15193106, DMS91057B, 193D048, 193D136, 60966446, 6096644-6 , 61334036, 6133403-6, 5910-01-177-9063, 01-177-9063, 5910011779063, 011779063
Electrical and Electronic Equipment Components | Capacitors
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 28 APR 1984 | 01-177-9063 | 00008 ( CAPACITOR, FIXED, ELECTROLYTIC ) |
Demand History | NSN 5910-01-177-9063
| Part Number | Request Date | QTY | Origin |
|---|---|---|---|
| 5910-01-177-9063 | 2012-10-286 | 45 | DIBBS |
Cross Reference | NSN 5910-01-177-9063
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 193D048 | 56289 | SPRAGUE ELECTRIC CO WORLD HQS |
| 193D136 | 56289 | SPRAGUE ELECTRIC CO WORLD HQS |
| 6096644-6 | 03640 | LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN |
| 6133403-6 | 03640 | LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN |
| DL15193106 | 56289 | SPRAGUE ELECTRIC CO WORLD HQS |
| DMS91057B | 16236 | DLA LAND AND MARITIME |
| H475M035 | 17554 | AVX TANTALUM CORPORATION DBA A V X |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5910-01-177-9063
Related Products | NSN 5910-01-177-9063
Technical Data | NSN 5910-01-177-9063
| Characteristic | Specifications |
|---|---|
| CAPACITANCE VALUE PER SECTION | 4.700 MICROFARADS SINGLE SECTION |
| TOLERANCE RANGE PER SECTION | -20.00 TO 20.00 PERCENT SINGLE SECTION |
| NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 35.0 DC SINGLE SECTION |
| NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
| BODY STYLE | 45A CHIP TYPE |
| BODY LENGTH | 0.320 INCHES NOMINAL |
| BODY WIDTH | 0.180 INCHES NOMINAL |
| BODY HEIGHT | 0.195 INCHES NOMINAL |
| SCHEMATIC DIAGRAM DESIGNATOR | 1C NO COMMON OR GROUNDED ELECTRODE(S) |
| TERMINAL TYPE AND QUANTITY | 2 BONDING PAD |
| TERMINAL LENGTH | 0.040 INCHES NOMINAL |
| CASE MATERIAL | METAL |
| CAPACITIVE ELECTRODE MATERIAL | TANTALUM |
| DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 4.0000 |
| DC LEAKAGE AT REFERENCE TEMP | 3.000 MICROAMPERES |
| ELECTRICAL POLARIZATION | POLARIZED |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| SPECIAL FEATURES | BURN-IN TEST |
| CRITICALITY CODE JUSTIFICATION | FEAT |
| III TERMINAL SURFACE TREATMENT | SOLDER |
| III ANODE TYPE | SOLID |
| III IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS | 0.23 |
| (NON-CORE DATA) OVERALL LENGTH | 0.400 INCHES NOMINAL |
| III DC LEAKAGE AT MAXIMUM OPERATING TEMP | 45.0 MICROAMPERES |
| (NON-CORE DATA) OVERALL HEIGHT | 0.195 INCHES NOMINAL |
| (NON-CORE DATA) OVERALL WIDTH | 0.180 INCHES NOMINAL |
Restrictions/Controls & Freight Information | NSN 5910-01-177-9063
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | Y | The item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 061400 | CONDENSERS/PARTS NOI/CAPACITORS |
| Less than car load rating | ||
| Less than truck load rating | P | 77.5 |
| Water commodity Code | 72D | unknown |
| Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5910-01-177-9063
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |