Product Details | ELECTROLYTIC FIXED CAPACITOR

5910-01-190-6301 A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Part Alternates: M39018/03-0647, M39018/03-0747, M39018/03-1047M, M39018030647, M39018030747, M39018031047M, MIL-C-39018/3, MILC390183, 5910-01-190-6301, 01-190-6301, 5910011906301, 011906301

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 29-SEP-84 01-190-6301

Drawings & Photos | NSN 5910-01-190-6301


Demand History | NSN 5910-01-190-6301

Part Number Request Date QTY Origin
M39018030747 2019-08-214 5 Serbia

Cross Reference | NSN 5910-01-190-6301

Part Number Cage Code Manufacturer
0180-2270 28480 HEWLETT-PACKARD COMPANY DBA HEWLETT-PACKARD CO. OR HP
39D207G075FL4 56289 SPRAGUE ELECTRIC CO WORLD HQS
M39018-03-1047 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M39018/03-0647 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M39018/03-0747 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M39018/03-1047M 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M39018/03-1247M 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M39018/03-1347 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M39018/03-1347M 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MIL-C-39018/3 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-01-190-6301

Technical Data | NSN 5910-01-190-6301

Characteristic Specifications
CAPACITANCE VALUE PER SECTION 220.000 MICROFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION -10.00 TO 30.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 75.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 105.0 DEG CELSIUS MAXIMUM
BODY STYLE 26B W/O MTG FACILITIES, AXIAL TERMINALS
BODY DIAMETER 0.758 INCHES NOMINAL
BODY LENGTH 2.125 INCHES MINIMUM AND 2.328 INCHES MAXIMUM
SCHEMATIC DIAGRAM DESIGNATOR 3C ELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL
TERMINAL TYPE AND QUANTITY 2 UNINSULATED WIRE LEAD
TERMINAL LENGTH 2.500 INCHES NOMINAL
TERMINAL DIAMETER 0.040 INCHES NOMINAL
CASE MATERIAL METAL
CASE INSULATION MATERIAL PLASTIC
CAPACITIVE ELECTRODE MATERIAL ALUMINUM
EQUIVALENT SERIES RESISTANCE AT REFERENCE TEMP IN OHMS 0.60
DC LEAKAGE AT REFERENCE TEMP 68.000 MICROAMPERES
ELECTRICAL POLARIZATION POLARIZED
RELIABILITY INDICATOR ESTABLISHED
RELIABILITY FAILURE RATE LEVEL IN PERCENT 1.0000
TEST DATA DOCUMENT 81349-MIL-C-39018 SPECIFICATION
SPECIFICATION/STANDARD DATA 81349-MIL-C-39018/3 GOVERNMENT SPECIFICATION
III TERMINAL SURFACE TREATMENT SOLDER
III IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS 13.0
(NON-CORE DATA) OVERALL LENGTH 2.125 INCHES MINIMUM AND 2.328 INCHES MAXIMUM
III DC LEAKAGE AT MAXIMUM OPERATING TEMP 410.0 MICROAMPERES
(NON-CORE DATA) OVERALL HEIGHT 0.758 INCHES NOMINAL
(NON-CORE DATA) OVERALL WIDTH 0.758 INCHES NOMINAL
MANUFACTURERS CODE 81349
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE MIL-C-39018/3
MANUFACTURERS CODE 81349
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE M39018/03-1047M

Restrictions/Controls & Freight Information | NSN 5910-01-190-6301

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information