Product Details | ELECTROLYTIC FIXED CAPACITOR

5910-01-198-5898 A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Part Alternates: 290-0171-00, 30D665, 5910-01-198-5898, 01-198-5898, 5910011985898, 290017100, 011985898

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 10 JAN 1985 01-198-5898

Drawings & Photos | NSN 5910-01-198-5898


Cross Reference | NSN 5910-01-198-5898

Part Number Cage Code Manufacturer
290-0171-00 80009 TEKTRONIX, INC. DBA TEKTRONIX
30D665 56289 SPRAGUE ELECTRIC CO WORLD HQS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-01-198-5898

Technical Data | NSN 5910-01-198-5898

Characteristic Specifications
CAPACITANCE VALUE PER SECTION 0.100 MILLIFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION -10.00 TO 75.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 12.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP -40.0 DEG CELSIUS MINIMUM AND 105.0 DEG CELSIUS MAXIMUM
BODY STYLE 26B W/O MTG FACILITIES, AXIAL TERMINALS
BODY DIAMETER 0.385 INCHES NOMINAL
BODY LENGTH 0.848 INCHES NOMINAL
SCHEMATIC DIAGRAM DESIGNATOR 1C NO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL TYPE AND QUANTITY 2 UNINSULATED WIRE LEAD
TERMINAL LENGTH 1.500 INCHES MINIMUM
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT 27.0000
DC LEAKAGE AT REFERENCE TEMP 4.000 MICROAMPERES

Restrictions/Controls & Freight Information | NSN 5910-01-198-5898

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information