NSN 5910-01-214-8485 L03452, MILC3965, MIL-C-3965
Product Details | ELECTROLYTIC FIXED CAPACITOR
5910-01-214-8485 A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.
Part Alternates: L03452, MILC3965, MIL-C-3965, 634L50415, 634L504-15, 7N64 PC 114, 7N64PC114, 7N74PC20, 7N78PC91, 5910-01-214-8485, 01-214-8485, 5910012148485, 012148485
Electrical and Electronic Equipment Components | Capacitors
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 16 AUG 1985 | 01-214-8485 | 00008 ( CAPACITOR, FIXED, ELECTROLYTIC ) |
Cross Reference | NSN 5910-01-214-8485
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 634L504-15 | 24374 | BECHTEL TECHNICAL SERVICES INC MACHINERY APPARATUS OPN |
| 7N64 PC 114 | 02750 | EATON AEROSPACE LLC DIV ELECTRICAL SENSING & CONTROLS |
| 7N74PC20 | 06RP6 | DRS CONSOLIDATED CONTROLS, INC. |
| 7N78PC91 | 06RP6 | DRS CONSOLIDATED CONTROLS, INC. |
| L03452 | 16236 | DLA LAND AND MARITIME |
| MIL-C-3965 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5910-01-214-8485
Related Products | NSN 5910-01-214-8485
Technical Data | NSN 5910-01-214-8485
| Characteristic | Specifications |
|---|---|
| CAPACITANCE VALUE PER SECTION | 550.000 MICROFARADS SINGLE SECTION |
| TOLERANCE RANGE PER SECTION | -15.00 TO 75.00 PERCENT SINGLE SECTION |
| NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 75.0 DC SINGLE SECTION |
| NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
| BODY STYLE | 14A W/O MTG FACILITIES, TERMINAL(S) ON ONE SURFACE |
| BODY LENGTH | 1.275 INCHES NOMINAL |
| BODY WIDTH | 0.783 INCHES NOMINAL |
| BODY HEIGHT | 2.500 INCHES NOMINAL |
| SCHEMATIC DIAGRAM DESIGNATOR | 3C ELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL |
| TERMINAL TYPE AND QUANTITY | 2 TAB, SOLDER LUG |
| TERMINAL LENGTH | 0.364 INCHES NOMINAL |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.624 INCHES NOMINAL |
| CASE MATERIAL | METAL |
| CAPACITIVE ELECTRODE MATERIAL | TANTALUM |
| DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 20.0000 |
| DC LEAKAGE AT REFERENCE TEMP | 96.000 MICROAMPERES |
| ELECTRICAL POLARIZATION | POLARIZED |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| FEATURES PROVIDED | HERMETICALLY SEALED CASE |
| SPECIAL FEATURES | ITEM MUST COMPLY WITH REQUIREMENTS OF DEFENSE ELECTRONICS SUPPLY CENTER PRODUCTION STANDARD NO. L03452; FOR NAVY NUCLEAR PROPULSION PLANT PRODUCTS ONLY |
| CRITICALITY CODE JUSTIFICATION | FEAT |
| III TERMINAL SURFACE TREATMENT | SOLDER |
| III ANODE TYPE | ETCHED FOIL |
| III IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS | 7.2 |
| (NON-CORE DATA) OVERALL LENGTH | 1.378 INCHES MAXIMUM |
| (NON-CORE DATA) OVERALL WIDTH | 0.783 INCHES NOMINAL |
| (NON-CORE DATA) OVERALL HEIGHT | 2.864 INCHES NOMINAL |
| III DC LEAKAGE AT MAXIMUM | 770.0 MICROAMPERES |
Restrictions/Controls & Freight Information | NSN 5910-01-214-8485
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | Y | The item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application. |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| NMF Description | 061400 | CONDENSERS/PARTS NOI/CAPACITORS |
| Less than car load rating | ||
| Less than truck load rating | P | 77.5 |
| Water commodity Code | 72D | unknown |
| Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5910-01-214-8485
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 1H | Consumable material assigned to NAVICP MECH for inventory management Naval Inventory Control Point, Mechanicsburg |
| Special Material ID | X3 | Nuclear Reactor Plant (NRP) material under the technical cognizance of the NAVSEA 08 special designed, manufactured and/or treated for use in a NRP or controls thereof. This category includes all other NRP items which are not coded X2 or X4. |
| Issue Repair, or Requisition | BL | Submit/refer requisitions to NAVICP MECH. Centralized control for issue of repair parts for specific programs/equipments. |
| Special Material Content | 9 | Non-Hazardous or Non-Sensitive Item, does not require hazardous or special handling, packaging or precautions |
| Source of Supply | NRP | NAVICP-ERP 700 Robbins Avenue Philadelphia, PA 19111-5098 |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Reparability | M | Medium Demand Velocity Items (consumables) |
| Acquisition Advice Codes | D | DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |