Product Details | ELECTROLYTIC FIXED CAPACITOR

5910-01-216-0263 A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Part Alternates: T605017774, UFT280030, UFT-2800-30, 32790630074, 3279063-0074, 3279063-74, 604D282G030JP6, 604D282G030JPG, 5910-01-216-0263, 01-216-0263, 5910012160263, 012160263, 327906374

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 05 SEP 1985 01-216-0263

Drawings & Photos | NSN 5910-01-216-0263


Cross Reference | NSN 5910-01-216-0263

Part Number Cage Code Manufacturer
3279063-0074 53711 NAVAL SEA SYSTEMS COMMAND
3279063-74 10001 NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT
604D282G030JP6 56289 SPRAGUE ELECTRIC CO WORLD HQS
604D282G030JPG 56289 SPRAGUE ELECTRIC CO WORLD HQS
T605017774 36090 LOCKHEED MARTIN LIBRASCOPE CORP
UFT-2800-30 00853 CORNELL-DUBILIER MARKETING, INC.
UFT-2800-30 14655 CORNELL-DUBILIER ELECTRONICS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-01-216-0263

Technical Data | NSN 5910-01-216-0263

Characteristic Specifications
CAPACITANCE VALUE PER SECTION 2800.000 MICROFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION -10.00 TO 75.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 30.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 105.0 DEG CELSIUS MAXIMUM
BODY STYLE 26B W/O MTG FACILITIES, AXIAL TERMINALS
BODY DIAMETER 1.100 INCHES MAXIMUM
BODY LENGTH 2.900 INCHES MAXIMUM
SCHEMATIC DIAGRAM DESIGNATOR 5C TWO COMMON TERMINALS FOR EACH ELECTRODE
TERMINAL TYPE AND QUANTITY 4 UNINSULATED WIRE LEAD
TERMINAL LENGTH 2.000 INCHES MINIMUM
TERMINAL DIAMETER 0.040 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO DIAMETER 0.180 INCHES NOMINAL
CASE MATERIAL METAL
CASE INSULATION MATERIAL PLASTIC
CAPACITIVE ELECTRODE MATERIAL ALUMINUM
EQUIVALENT SERIES RESISTANCE AT REFERENCE TEMP IN OHMS 0.095
DC LEAKAGE AT REFERENCE TEMP 145.000 MICROAMPERES
ELECTRICAL POLARIZATION POLARIZED
RELIABILITY INDICATOR NOT ESTABLISHED
III TERMINAL SURFACE TREATMENT SOLDER
III ANODE TYPE PLAIN FOIL
III IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS 0.066
(NON-CORE DATA) OVERALL LENGTH 2.900 INCHES MAXIMUM
(NON-CORE DATA) OVERALL WIDTH 1.100 INCHES MAXIMUM
(NON-CORE DATA) OVERALL HEIGHT 1.100 INCHES MAXIMUM
III DC LEAKAGE AT MAXIMUM OPERATING TEMP 870.0 MICROAMPERES

Restrictions/Controls & Freight Information | NSN 5910-01-216-0263

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061400 CONDENSERS/PARTS NOI/CAPACITORS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5910-01-216-0263

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each