Product Details | ELECTROLYTIC FIXED CAPACITOR

5910-01-275-5831 A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Part Alternates: CWR06JC226KR, MIL-C-55365/4, MILC553654, 5910-01-275-5831, 01-275-5831, 5910012755831, 012755831

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 01-275-5831

Drawings & Photos | NSN 5910-01-275-5831


Cross Reference | NSN 5910-01-275-5831

Part Number Cage Code Manufacturer
CWR06JA226KC 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
CWR06JC226KC 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
CWR06JC226KR 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
CWR06JC226MM 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MIL-C-55365/4 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-01-275-5831

Technical Data | NSN 5910-01-275-5831

Characteristic Specifications
CAPACITANCE VALUE PER SECTION 22.000 MICROFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION -10.00 TO 10.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 20.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
BODY STYLE 45A CHIP TYPE
BODY LENGTH 0.270 INCHES MINIMUM AND 0.290 INCHES MAXIMUM
BODY WIDTH 0.135 INCHES MINIMUM AND 0.165 INCHES MAXIMUM
BODY HEIGHT 0.095 INCHES MINIMUM AND 0.125 INCHES MAXIMUM
SCHEMATIC DIAGRAM DESIGNATOR 1C NO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL TYPE AND QUANTITY 2 BONDING PAD
TERMINAL LENGTH 0.045 INCHES MINIMUM AND 0.055 INCHES MAXIMUM
CASE MATERIAL CERAMIC
CAPACITIVE ELECTRODE MATERIAL TANTALUM
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT 6.000
DC LEAKAGE AT REFERENCE TEMP 4.000 MICROAMPERES
ELECTRICAL POLARIZATION POLARIZED
RELIABILITY INDICATOR ESTABLISHED
RELIABILITY FAILURE RATE LEVEL IN PERCENT 0.010
SPECIAL FEATURES WEIBULL GRADED FAILURE RATE
TEST DATA DOCUMENT 81349-MIL-C-55365 SPECIFICATION
SPECIFICATION/STANDARD DATA 81349-MIL-C-55365/4 GOVERNMENT SPECIFICATION
CRITICALITY CODE JUSTIFICATION FEAT
III TERMINAL SURFACE TREATMENT SOLDER
III ANODE TYPE SOLID
(NON-CORE DATA) OVERALL LENGTH 0.270 INCHES MINIMUM AND 0.290 INCHES MAXIMUM
III DC LEAKAGE AT MAXIMUM OPERATING TEMP 40.0 MICROAMPERES
(NON-CORE DATA) OVERALL HEIGHT 0.095 INCHES MINIMUM AND 0.125 INCHES MAXIMUM
(NON-CORE DATA) OVERALL WIDTH 0.135 INCHES MINIMUM AND 0.165 INCHES MAXIMUM
MANUFACTURERS CODE 81349
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE CWR06JC226KR
MANUFACTURERS CODE 81349
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE MIL-C-55365/4

Restrictions/Controls & Freight Information | NSN 5910-01-275-5831

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Category Code Description
No Freight Information