Product Details | ELECTROLYTIC FIXED CAPACITOR

5910-01-291-2851 A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Part Alternates: UHA10053 , 02010605, 02-0106-05, 5910-01-291-2851, 01-291-2851, 5910012912851, 012912851

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 26 DEC 1988 01-291-2851

Drawings & Photos | NSN 5910-01-291-2851


Demand History | NSN 5910-01-291-2851

Part Number Request Date QTY Origin
02-0106-05 2023-06-152 22 DIBBS
UHA10053 2023-06-152 22 DIBBS
02-0106-05 2023-05-138 15 DIBBS
UHA10053 2023-05-138 15 DIBBS
02-0106-05 2022-04-119 45 DIBBS
UHA10053 2022-04-119 45 DIBBS
02-0106-05 2022-04-108 45 DIBBS
UHA10053 2022-04-108 45 DIBBS
02-0106-05 2022-01-03 9 DIBBS
UHA10053 2022-01-03 9 DIBBS
02-0106-05 2021-12-346 2 DIBBS
UHA10053 2021-12-346 2 DIBBS
02-0106-05 2021-07-196 9 DIBBS
UHA10053 2021-07-196 9 DIBBS
02-0106-05 2021-02-42 16 DIBBS
UHA10053 2021-02-42 16 DIBBS
02-0106-05 2019-01-24 24 DIBBS
UHA10053 2019-01-24 24 DIBBS
5910-01-291-2851 2016-09-258 1 Thailand
5910-01-291-2851 2015-04-103 39 DIBBS
5910-01-291-2851 2015-04-92 39 DIBBS
5910-01-291-2851 2014-09-261 36 DIBBS
5910-01-291-2851 2014-05-126 22 DIBBS
5910-01-291-2851 2012-08-227 62 DIBBS
5910-01-291-2851 2011-03-76 60 DIBBS

Cross Reference | NSN 5910-01-291-2851

Part Number Cage Code Manufacturer
02-0106-05 31435 LUCAS AEROSPACE POWER EQUIPMENT CORPORATION
02-0106-05 3CPE0 SAFRAN POWER USA, LLC
UHA10053 00853 CORNELL-DUBILIER MARKETING, INC.
UHA10053 14655 CORNELL-DUBILIER ELECTRONICS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-01-291-2851

Technical Data | NSN 5910-01-291-2851

Characteristic Specifications
CAPACITANCE VALUE PER SECTION 500.000 MICROFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION -10.00 TO 75.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 75.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 105.0 DEG CELSIUS MAXIMUM
BODY STYLE 26B W/O MTG FACILITIES, AXIAL TERMINALS
BODY DIAMETER 0.968 INCHES MINIMUM AND 1.032 INCHES MAXIMUM
BODY LENGTH 2.687 INCHES MINIMUM AND 3.563 INCHES MAXIMUM
SCHEMATIC DIAGRAM DESIGNATOR 2C ELECTRODE(S) GROUNDED TO CASE
TERMINAL TYPE AND QUANTITY 2 UNINSULATED WIRE LEAD
TERMINAL LENGTH 2.750 INCHES NOMINAL
TERMINAL DIAMETER 0.040 INCHES NOMINAL
CASE MATERIAL METAL
CASE INSULATION MATERIAL PLASTIC
CAPACITIVE ELECTRODE MATERIAL ALUMINUM
EQUIVALENT SERIES RESISTANCE AT REFERENCE TEMP IN OHMS 0.065
DC LEAKAGE AT REFERENCE TEMP 97.000 MICROAMPERES
ELECTRICAL POLARIZATION POLARIZED
RELIABILITY INDICATOR NOT ESTABLISHED
III TERMINAL SURFACE TREATMENT SOLDER
III ANODE TYPE ETCHED FOIL
III IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS 0.042
(NON-CORE DATA) OVERALL LENGTH 2.687 INCHES MINIMUM AND 3.563 INCHES MAXIMUM
(NON-CORE DATA) OVERALL HEIGHT 0.968 INCHES MINIMUM AND 1.032 INCHES MAXIMUM
(NON-CORE DATA) OVERALL WIDTH 0.968 INCHES MINIMUM AND 1.032 INCHES MAXIMUM

Restrictions/Controls & Freight Information | NSN 5910-01-291-2851

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061400 CONDENSERS/PARTS NOI/CAPACITORS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5910-01-291-2851

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesDDoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each