Product Details | ELECTROLYTIC FIXED CAPACITOR

5910-01-540-7479 A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Part Alternates: TAJA684K035R, 5910-01-540-7479, 01-540-7479, 5910015407479, 015407479

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 01 JUN 2006 01-540-7479

Drawings & Photos | NSN 5910-01-540-7479


Cross Reference | NSN 5910-01-540-7479

Part Number Cage Code Manufacturer
TAJA684K035R 04222 AVX CORPORATION DBA OLEAN ADVANCED PRODUCTS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-01-540-7479

Technical Data | NSN 5910-01-540-7479

Characteristic Specifications
CAPACITANCE VALUE PER SECTION 0.680 MICROFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION -10.00 TO 10.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 35.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM
BODY STYLE 21A W/O MTG FACILITIES, TERMINALS ON OPPOSITE SURFACES
BODY LENGTH 3.000 INCHES MINIMUM AND 3.400 INCHES MAXIMUM
BODY WIDTH 1.500 INCHES MINIMUM AND 1.800 INCHES MAXIMUM
BODY HEIGHT 1.500 INCHES MINIMUM AND 1.800 INCHES MAXIMUM
CAPACITIVE ELECTRODE MATERIAL TANTALUM
RELIABILITY INDICATOR NOT ESTABLISHED

Restrictions/Controls & Freight Information | NSN 5910-01-540-7479

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information