Product Details | LOW PASS FILTER

5915-00-064-0750 An item designed to pass all frequencies below a specified frequency. Excludes a single inductance, a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).

Part Alternates: WFV32351, WFV3235-1, 32-266072-2, 2F130, 5915-00-064-0750, 00-064-0750, 5915000640750, 000640750, 322660722

Electrical and Electronic Equipment Components | Filters and Networks

Supply Group (FSG) NSN Assign. NIIN
59 22 JUN 1967 00-064-0750

Drawings & Photos | NSN 5915-00-064-0750


Cross Reference | NSN 5915-00-064-0750

Part Number Cage Code Manufacturer
2F130 13058 SORA POWER INC.
32-266072-2 04655 GENERAL DYNAMICS C4 SYSTEMS, INC.
WFV3235-1 93790 CORNELL-DUBILIER ELECTRONICS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5915-00-064-0750

Technical Data | NSN 5915-00-064-0750

Characteristic Specifications
REFERENCE FREQUENCY PER FUNCTION 850.0 HERTZ BLANK
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS 1.0 BLANK
FREQUENCY BAND WIDTH PER FUNCTION 600.00 HERTZ BLANK AND 1.10 KILOHERTZ BLANK
SOURCE IMPEDANCE RATING PER FUNCTION 600.0 OHMS BLANK
LOAD IMPEDANCE PER FUNCTION 600.0 OHMS BLANK
INPUT IMPEDANCE PER FUNCTION W/LOAD 600.0 OHMS BLANK
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT 600.0 OHMS BLANK AND 600.0 OHMS BLANK
INCLOSURE TYPE ENCASED
FUNCTIONAL TERMINAL TYPE AND QUANTITY 2 THREADED STUD OUTPUT
STYLE DESIGNATOR 2 RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
OVERALL HEIGHT 5.870 INCHES NOMINAL
BODY LENGTH 1.800 INCHES NOMINAL
BODY HEIGHT 5.500 INCHES NOMINAL
BODY WIDTH 1.500 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED STUD
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 1.250 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 1.000 INCHES NOMINAL
III DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS 1.0 NOMINAL BLANK AND 1.0 NOMINAL BLANK AND 60.0 NOMINAL BLANK AND 60.0 NOMINAL BLANK
III MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE 100.0 VOLTS AT SEA LEVEL
III OPERATING TEMP RANGE -10.0 TO 40.0 DEG CELSIUS

Restrictions/Controls & Freight Information | NSN 5915-00-064-0750

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061400 CONDENSERS/PARTS NOI/CAPACITORS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code SG 403 SCMS/GUED
5215 Thurlow St, Suite 5, Bldg 70C
Wright-Patterson AFB OH 45433
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5915-00-064-0750

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeAHSU:LGM-30 MINUTEMAN
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each