NSN 5915-00-882-2732 LT3000AB, 1292032P2, 00-882-2732
Product Details | LOW PASS FILTER
5915-00-882-2732 An item designed to pass all frequencies below a specified frequency. Excludes a single inductance, a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).
Part Alternates: LT3000AB, 1292032P2, 5915-00-882-2732, 00-882-2732, 5915008822732, 008822732
Electrical and Electronic Equipment Components | Filters and Networks
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 10 NOV 1967 | 00-882-2732 | 13911 ( FILTER, LOW PASS ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5915-00-882-2732
Related Products | NSN 5915-00-882-2732
Technical Data | NSN 5915-00-882-2732
| Characteristic | Specifications |
|---|---|
| REFERENCE FREQUENCY PER FUNCTION | 1.5 GIGAHERTZ BLANK |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 0.3 BLANK |
| FREQUENCY BAND WIDTH PER FUNCTION | 0.00 HERTZ BLANK AND 3.00 GIGAHERTZ BLANK |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS BLANK |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS BLANK |
| INCLOSURE TYPE | ENCASED |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE INPUT 1 CONNECTOR, RECEPTACLE OUTPUT |
| STYLE DESIGNATOR | 26 ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| OVERALL LENGTH | 3.910 INCHES NOMINAL |
| BODY OUTSIDE DIAMETER | 0.310 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 TERMINAL |
| III SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 0.00 HERTZ BLANK AND 3.00 GIGAHERTZ BLANK AND 5.10 GIGAHERTZ BLANK AND 15.00 GIGAHERTZ BLANK |
| III DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 0.3 MAXIMUM BLANK AND 0.3 MAXIMUM BLANK AND 60.0 MINIMUM BLANK AND 60.0 MINIMUM BLANK |
| III INPUT TERMINAL MANUFACTURER CODE | 80058 |
| III INPUT TERMINAL IDENTIFICATION | UG21B/U |
| III OUTPUT TERMINAL MANUFACTURER CODE | 80058 |
| III OUTPUT TERMINAL IDENTIFICATION | UG23B/U |
| III MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE | 700.0 VOLTS AT SEA LEVEL |
| III VIBRATION RESISTANCE RANGE IN HERTZ | 10.0 TO 55.0 |
| III OPERATING TEMP RANGE | 0.0 TO 85.0 DEG CELSIUS |
| III BODY MATERIAL | METAL |
Restrictions/Controls & Freight Information | NSN 5915-00-882-2732
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | U | Precious metal type is unknown |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 061400 | CONDENSERS/PARTS NOI/CAPACITORS |
| Less than car load rating | ||
| Less than truck load rating | P | 77.5 |
| Water commodity Code | 72D | unknown |
| Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5915-00-882-2732
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |