NSN 5915-01-336-7667 A5754, A-5754, CNA 2007-04
Product Details | RADIO FREQUENCY INTERFERENCE FILTER
5915-01-336-7667 An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.
Part Alternates: A5754, A-5754, CNA 2007-04, CNA200704, RF13111, WF21649, 50038185, 5003-8185, 8417871, 841787-1, 5915-01-336-7667, 01-336-7667, 5915013367667, 013367667
Electrical and Electronic Equipment Components | Filters and Networks
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 03 APR 1991 | 01-336-7667 | 00765 ( FILTER, RADIO FREQUENCY INTERFERENCE ) |
Demand History | NSN 5915-01-336-7667
| Part Number | Request Date | QTY | Origin |
|---|---|---|---|
| 5915-01-336-7667 | 2009-02-50 | 6 | DIBBS |
| 5915-01-336-7667 | 2007-01-24 | 4 | DIBBS |
Cross Reference | NSN 5915-01-336-7667
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 5003-8185 | 13050 | SPECTRUM CONTROL, INC. DIV API TECHNOLOGIES - EIS/WESSON |
| 841787-1 | 06481 | NORTHROP GRUMMAN SYSTEMS CORPORATION |
| 841787-1 | 13973 | LITTON SYSTEMS INC. DIV NAVIGATION SYSTEMS DIVISION |
| A-5754 | 23939 | THE CAPTOR CORPORATION |
| CNA 2007-04 | 66230 | PACIFIC AEROSPACE & ELECTRONICS, INC. |
| RF13111 | 13619 | EMS DEVELOPMENT CORPORATION |
| WF21649 | 05245 | CORCOM INC DIV CIS/CORCOM |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5915-01-336-7667
Technical Data | NSN 5915-01-336-7667
| Characteristic | Specifications |
|---|---|
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 50.0 OHMS 2ND RADIO INTERFERENCE 50.0 OHMS 3RD RADIO INTERFERENCE 50.0 OHMS 4TH RADIO INTERFERENCE |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 50.0 OHMS 2ND RADIO INTERFERENCE 50.0 OHMS 3RD RADIO INTERFERENCE 50.0 OHMS 4TH RADIO INTERFERENCE |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 208.0 VOLTS AC 1ST RADIO INTERFERENCE 208.0 VOLTS AC 2ND RADIO INTERFERENCE 208.0 VOLTS AC 3RD RADIO INTERFERENCE 208.0 VOLTS AC 4TH RADIO INTERFERENCE |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 440.0 1ST RADIO INTERFERENCE 440.0 2ND RADIO INTERFERENCE 440.0 3RD RADIO INTERFERENCE 440.0 4TH RADIO INTERFERENCE |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 15.0 1ST RADIO INTERFERENCE 15.0 2ND RADIO INTERFERENCE 15.0 3RD RADIO INTERFERENCE 15.0 4TH RADIO INTERFERENCE |
| MAXIMUM VOLTAGE DROP PER FUNCTION | 2.08 VOLTS AC 1ST RADIO INTERFERENCE 2.08 VOLTS AC 2ND RADIO INTERFERENCE 2.08 VOLTS AC 3RD RADIO INTERFERENCE 2.08 VOLTS AC 4TH RADIO INTERFERENCE |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, PLUG INPUT 1 CONNECTOR, PLUG OUTPUT |
| STYLE DESIGNATOR | 38 RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
| OVERALL HEIGHT | 2.637 INCHES NOMINAL |
| BODY LENGTH | 10.000 INCHES NOMINAL |
| BODY HEIGHT | 2.200 INCHES MAXIMUM |
| BODY WIDTH | 8.000 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 SLOT |
| MOUNTING SLOT WIDTH | 0.220 INCHES NOMINAL |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 10.880 INCHES NOMINAL |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 6.500 INCHES NOMINAL |
| FEATURES PROVIDED | FUNGUS RESISTANT AND SHOCK RESISTANT |
| SPECIAL FEATURES | FOUR FILTERED FUNCTIONS; FIVE UNFILTERED FUNCTIONS; FOUR CHASIS GROUND PINS |
| III PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE INDUCTANCE-CAPACITANCE 3RD RADIO |
Restrictions/Controls & Freight Information | NSN 5915-01-336-7667
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | D | Munitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.) |
| Controlled Inventory Item Code: | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 061990 | ELECTRICAL EQUIP:FILTERS |
| Less than car load rating | ||
| Less than truck load rating | P | 77.5 |
| Water commodity Code | 72D | unknown |
| Originating Activity Code | TH | Defense Supply Center Columbus Columbus, OH 43215 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5915-01-336-7667
| Category | Code | Description |
|---|---|---|
| Budget Code | 9 | General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors. |
| Materiel Management Aggregation Code | EH | SX:ELECTRONIC COMPONENTS |
| Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
| Fund Code | SF | Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point. |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DF | Department of the Air Force |
| Service Organization | F | U.S. Air Force |
| Reparability | N | Stock Fund (except Munitions) |
| Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
| Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |