Product Details | ROTARY SWITCH

5930-00-491-4500 A switch actuated by a definite angular rotation of the switch shaft about its axis. For items having rated actuation travel and pressure characteristics, see SWITCH, SENSITIVE. Excludes RELAY, ROTARY; SWITCH, STEPPING; and SWITCH, TELEPHONE (as modified).

Part Alternates: 54177, 73118201, 7311-8201, 5930-00-491-4500, 00-491-4500, 5930004914500, 004914500

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 04 JUN 1969 00-491-4500

Cross Reference | NSN 5930-00-491-4500

Part Number Cage Code Manufacturer
54177 58756 CTS CORP ELECTROMECHANICAL DIV
54177 71450 CTS CORP
7311-8201 15455 ELGENCO INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-00-491-4500

Technical Data | NSN 5930-00-491-4500

Characteristic Specifications
INDIVIDUAL SECTION QUANTITY 2
SWITCH CONTACT BASIC DESIGN NONPILE-UP SYMMETRICAL
SWITCH ACTUATOR INDEXING POSITION QUANTITY 5 SINGLE ACTUATOR
SWITCH ACTUATOR STOP DEVICE TYPE FIXED STOP SINGLE ACTUATOR
SHAFT DIAMETER 0.250 INCHES NOMINAL SINGLE ACTUATOR
SHAFT LENGTH 1.406 INCHES NOMINAL SINGLE ACTUATOR
TERMINAL TYPE TAB, SOLDER LUG
MOUNTING METHOD THREADED BUSHING SINGLE MOUNTING FACILITY
NOMINAL THREAD SIZE 0.375 INCHES SINGLE MOUNTING FACILITY
THREAD QUANTITY PER INCH 32 SINGLE MOUNTING FACILITY
THREAD LENGTH 0.219 INCHES NOMINAL SINGLE MOUNTING FACILITY

Restrictions/Controls & Freight Information | NSN 5930-00-491-4500

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5930-00-491-4500

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each