Product Details | THERMOSTATIC SWITCH

5930-01-279-9733 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Part Alternates: 131871, 13187-1, 20601L81L1804, 5930-01-279-9733, 01-279-9733, 5930012799733, 012799733

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 27 MAY 1988 01-279-9733

Drawings & Photos | NSN 5930-01-279-9733


Cross Reference | NSN 5930-01-279-9733

Part Number Cage Code Manufacturer
13187-1 5RQL2 DRS ENVIRONMENTAL SYSTEMS, INC. DBA D R S
13187-1 90598 ENGINEERED AIR SYSTEMS INC. DBA DRS SUSTAINMENT SYSTEMS
20601L8-1,L180-4 14859 TEXAS INSTRUMENTS INC CONTROL PRODUCTS DIV

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-01-279-9733

Technical Data | NSN 5930-01-279-9733

Characteristic Specifications
STYLE DESIGNATOR 65 DISC W/FLANGE
OVERALL LENGTH 2.000 INCHES NOMINAL
OVERALL HEIGHT 1.015 INCHES MAXIMUM
BODY DIAMETER 0.920 INCHES NOMINAL
BODY HEIGHT 0.750 INCHES NOMINAL
NONPILE-UP CONTACT ARRANGEMENT 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE
CONTACT STIMULUS RATING 180.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 140.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT
CONTACT VOLTAGE RATING IN VOLTS 120.0 AC AT SEA LEVEL SINGLE VOLTAGE
CONTACT LOAD CURRENT RATING 25.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE
MEDIA FOR WHICH DESIGNED GAS OR LIQUID
TEMP SENSING ELEMENT TYPE INTERNAL SENSOR
TERMINAL TYPE QUICK DISCONNECT, MALE
MOUNTING METHOD FLANGE AND SLOT
MOUNTING SLOT WIDTH 0.156 INCHES NOMINAL
MOUNTING FACILITY PATTERN TWO POSITION IN-LINE
DISTANCE BETWEEN MOUNTING FACILITY CENTERS 1.625 INCHES NOMINAL
III HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION DUSTPROOF

Restrictions/Controls & Freight Information | NSN 5930-01-279-9733

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code TH Defense Supply Center Columbus
Columbus, OH 43215
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5930-01-279-9733

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each