Product Details | CONNECTOR ADAPTER

5935-00-269-4639 An adapter with electrical contacts which provides facilities for joining two or more electrical connectors, whose design or function will not normally warrant their junction. It is not designed for permanent attachment to a cable, cord, coaxial line, or wire. The physical shape of an electrical connector should not be the determining factor of its name. Tee, angle, straight, and Y-shaped adapters are all ADAPTER, CONNECTOR. Excludes ADAPTER, CONNECTOR TO LAMPBASE; ADAPTER, LAMPHOLDER TO CONNECTOR; ADAPTER (1), CABLE CLAMP TO CONNECTOR; and ADAPTER, LAMPHOLDER. For items designed as a mechanical connection between an electrical conduit and an electrical connector, see ADAPTER (1), ELECTRICAL CONDUIT.

Part Alternates: REB49408, UG1019/U, UG1019AU, UG1019U, 13154339, 3579636000, 357-9636-000, 4117581, 411758-1, 5935-00-269-4639, 00-269-4639, 5935002694639, 002694639

Electrical and Electronic Equipment Components | Connectors, Electrical

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1963 00-269-4639

Drawings & Photos | NSN 5935-00-269-4639


Demand History | NSN 5935-00-269-4639

Part Number Request Date QTY Origin
357-9636-000 2024-08-214 223 DIBBS
357-9636-000 2024-02-36 249 DIBBS
357-9636-000 2024-01-25 249 DIBBS
357-9636-000 2023-05-135 231 DIBBS
357-9636-000 2023-05-124 231 DIBBS
357-9636-000 2022-10-290 93 DIBBS
5935-00-269-4639 2009-02-42 156 DIBBS
5935-00-269-4639 2008-04-114 79 DIBBS
5935-00-269-4639 2007-09-248 500 DIBBS

Cross Reference | NSN 5935-00-269-4639

Part Number Cage Code Manufacturer
13154339 18876 U S ARMY AVIATION AND MISSILE COMMAND
357-9636-000 95105 ROCKWELL COLLINS, INC. DIV GOVERNMENT SYSTEMS - DALLAS
411758-1 96214 RAYTHEON COMPANY DBA RAYTHEON
REB49408 80064 NAVAL SHIP SYSTEMS COMMAND
UG1019/U 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
UG1019AU 80058 JOINT ELECTRONICS TYPE DESIGNATION SYSTEM
UG1019AU 91836 WINCHESTER ELECTRONICS CORPORATION DBA KINGS ELECTRONICS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5935-00-269-4639

Technical Data | NSN 5935-00-269-4639

Characteristic Specifications
BODY STYLE 12N STRAIGHT SHAPE, EXTERNAL COUPLING
OVERALL LENGTH 1.938 INCHES NOMINAL
OVERALL DIAMETER 1.063 INCHES NOMINAL
BUSHING ACCOMMODATION HOLE SHAPE ROUND
CONNECTOR LOCKING METHOD EXTERNALLY THREADED SHELL
THREADED DEVICE TYPE COUPLING FACILITY AND MOUNTING BUSHING
THREAD SERIES DESIGNATOR UNEF
NOMINAL THREAD SIZE 0.750 INCHES
THREAD CLASS 2A AND 2A
THREAD QUANTITY PER INCH 20
THREAD DIRECTION RIGHT-HAND
SHELL TYPE SOLID
SHELL MATERIAL COPPER ALLOY
MATING END QUANTITY 2
CONTACT POSITION ARRANGEMENT STYLE ABDB NONSTD ALL MATING ENDS
INSERT MATERIAL PLASTIC ALL MATING ENDS
INCLUDED CONTACT QUANTITY 2 ALL MATING ENDS SINGLE CONTACT GROUPING
CONTACT REMOVABILITY NONREMOVABLE ALL MATING ENDS SINGLE CONTACT GROUPING
INCLUDED CONTACT TYPE COAXIAL SOCKET ALL MATING ENDS SINGLE CONTACT GROUPING
RADIO FREQUENCY TYPE CONTACT CHARACTERISTIC IMPEDANCE IN OHMS 50.0 ALL MATING ENDS SINGLE CONTACT GROUPING
ENVIRONMENTAL PROTECTION SALT WATER RESISTANT

Restrictions/Controls & Freight Information | NSN 5935-00-269-4639

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061680 ELEC WIRING PLUGS ETC
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 658 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5935-00-269-4639

Category Code Description
Materiel Category and Inventory ManagerQ Electronics Materiel (DLA/GSA Items)
Appropriation and Budget Activity2 Stock Fund Secondary Items
Management Inventory Segment2 NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable.
Specific Group/Generic CodeQ Avionics
Weapons Systems/End Item or Homogeneous GroupQKATC Support
Accounting Requirements CodeX Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDADepartment of the Army
Service OrganizationAU.S. Army
ReparabilityZThis is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item.
Acquisition Advice CodesDDoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Price ValidationV The current standard price has been validated.
  • The item has been analyzed in conjunction with the Zero Overpricing Program and is in the accepted price range.
  • The item was procured under open competition and under the competitive arena the price is considered fair and reasonable.
  • ZOP or Standard price challenges are permissible but must be supported by adequate justification.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesDDoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesDDoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each