NSN 5935-01-094-1417 SF11026002, SF1102-6002, SF11296117
Product Details | CONNECTOR ADAPTER
5935-01-094-1417 An adapter with electrical contacts which provides facilities for joining two or more electrical connectors, whose design or function will not normally warrant their junction. It is not designed for permanent attachment to a cable, cord, coaxial line, or wire. The physical shape of an electrical connector should not be the determining factor of its name. Tee, angle, straight, and Y-shaped adapters are all ADAPTER, CONNECTOR. Excludes ADAPTER, CONNECTOR TO LAMPBASE; ADAPTER, LAMPHOLDER TO CONNECTOR; ADAPTER (1), CABLE CLAMP TO CONNECTOR; and ADAPTER, LAMPHOLDER. For items designed as a mechanical connection between an electrical conduit and an electrical connector, see ADAPTER (1), ELECTRICAL CONDUIT.
Part Alternates: SF11026002, SF1102-6002, SF11296117, SF1129-6117 , 10044686101, 10044686-101, 11026002, 1102-6002, 2225000K0912, 2225-000-K091-2 , 3180224200, 3180-2242-00, 50675690189, 50-675-6901-89, 5935-01-094-1417, 01-094-1417, 5935010941417, 010941417
Electrical and Electronic Equipment Components | Connectors, Electrical
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 03 MAY 1980 | 01-094-1417 | 15091 ( ADAPTER, CONNECTOR ) |
Demand History | NSN 5935-01-094-1417
| Part Number | Request Date | QTY | Origin |
|---|---|---|---|
| 5935-01-094-1417 | 2015-10-293 | 107 | DIBBS |
| 5935-01-094-1417 | 2013-10-282 | 83 | DIBBS |
| 5935-01-094-1417 | 2013-09-260 | 87 | DIBBS |
| 5935-01-094-1417 | 2013-08-216 | 71 | DIBBS |
| 5935-01-094-1417 | 2013-06-156 | 87 | DIBBS |
| 5935-01-094-1417 | 2009-11-334 | 6 | DIBBS |
| 5935-01-094-1417 | 2007-03-80 | 21 | DIBBS |
Cross Reference | NSN 5935-01-094-1417
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 10044686-101 | 94580 | HONEYWELL INTERNATIONAL INC. DBA HONEYWELL |
| 1102-6002 | 95077 | SV MICROWAVE, INC DIV SV MICROWAVE |
| 2225-000-K091-2 | 00795 | DELTA ELECTRONICS MFG CORP |
| 3180-2242-00 | 96341 | COBHAM ELECTRONIC SYSTEMS INC. DBA COBHAM DEFENSE ELECTRONICS |
| 3180-2242-00 | DG438 | SEMIC RF ELECTRONIC GMBH |
| 50-675-6901-89 | 98291 | ITT CANNON RF PRODUCTS |
| SF1102-6002 | 95077 | SV MICROWAVE, INC DIV SV MICROWAVE |
| SF1129-6117 | 95077 | SV MICROWAVE, INC DIV SV MICROWAVE |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5935-01-094-1417
Technical Data | NSN 5935-01-094-1417
| Characteristic | Specifications |
|---|---|
| BODY STYLE | 8N STRAIGHT SHAPE W/FLANGE |
| OVERALL LENGTH | 1.010 INCHES MAXIMUM |
| OVERALL HEIGHT | 0.700 INCHES MAXIMUM |
| OVERALL WIDTH | 0.700 INCHES MAXIMUM |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 0.499 INCHES MINIMUM AND 0.501 INCHES MAXIMUM |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.499 INCHES MINIMUM AND 0.501 INCHES MAXIMUM |
| DISTANCE FROM MOUNTING SHOULDER TO FRONT FACE | 0.596 INCHES MAXIMUM |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.123 INCHES MINIMUM AND 0.133 INCHES MAXIMUM |
| CONNECTOR LOCKING METHOD | EXTERNALLY THREADED SHELL |
| THREADED DEVICE TYPE | COUPLING FACILITY |
| THREAD SERIES DESIGNATOR | UNEF AND UNS |
| NOMINAL THREAD SIZE | 0.250 INCHES AND 0.438 INCHES |
| THREAD CLASS | 2A AND 2A |
| THREAD QUANTITY PER INCH | 36 AND 28 |
| THREAD DIRECTION | RIGHT-HAND AND RIGHT-HAND |
| NOMINAL THREAD LENGTH | 0.150 INCHES AND 0.187 INCHES |
| SHELL TYPE | SOLID |
| SHELL MATERIAL | STEEL COMP 303 |
| SHELL MATERIAL DOCUMENT AND CLASSIFICATION | QQ-S-764D,CLASS 303,COND,A FED SPEC SINGLE MATERIAL RESPONSE |
| MATING END QUANTITY | 2 |
| CONTACT POSITION ARRANGEMENT STYLE | ABCZ TNC 1ST MATING END ABDN SMA 2ND MATING END |
| INSERT MATERIAL | PLASTIC FLUOROCARBON SINGLE MATING END |
| INSERT MATERIAL DOCUMENT AND CLASSIFICATION | MIL-P-19468 MIL SPEC SINGLE MATERIAL RESPONSE SINGLE MATING END |
| INCLUDED CONTACT QUANTITY | 1 ALL MATING ENDS SINGLE CONTACT GROUPING |
| CONTACT REMOVABILITY | NONREMOVABLE ALL MATING ENDS SINGLE CONTACT GROUPING |
| INCLUDED CONTACT TYPE | COAXIAL SOCKET ALL MATING ENDS SINGLE CONTACT GROUPING |
| RADIO FREQUENCY TYPE CONTACT CHARACTERISTIC IMPEDANCE IN OHMS | 50.0 ALL MATING ENDS SINGLE CONTACT GROUPING |
| CONTACT MAXIMUM FREQUENCY RATING | 4400.0 MEGAHERTZ ALL MATING ENDS SINGLE CONTACT GROUPING |
| CONTACT MATERIAL | COPPER ALLOY ALL MATING ENDS SINGLE CONTACT GROUPING |
| CONTACT MATERIAL DOCUMENT AND CLASSIFICATION | QQ-C-530,1/2 HARD FED SPEC SINGLE MATERIAL RESPONSE ALL MATING ENDS SINGLE CONTACT GROUPING |
| CONTACT SURFACE TREATMENT | GOLD ALL MATING ENDS SINGLE CONTACT GROUPING |
| CONTACT SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | MIL-G-45204A,TYPE I OR II,CLASS 2 MIL SPEC SINGLE TREATMENT RESPONSE ALL MATING ENDS SINGLE CONTACT GROUPING |
Restrictions/Controls & Freight Information | NSN 5935-01-094-1417
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
| Precious Metals Indicator Code: | G | Item contains gold |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 061680 | ELEC WIRING PLUGS ETC |
| Less than car load rating | ||
| Less than truck load rating | W | Rating Variable |
| Water commodity Code | 658 | unknown |
| Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5935-01-094-1417
| Category | Code | Description |
|---|---|---|
| Budget Code | 9 | General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors. |
| Materiel Management Aggregation Code | EH | SX:ELECTRONIC COMPONENTS |
| Fund Code | SF | Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point. |
| Price Validation | V | The current standard price has been validated.
|
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DF | Department of the Air Force |
| Service Organization | F | U.S. Air Force |
| Reparability | N | Stock Fund (except Munitions) |
| Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |