Product Details | ELECTROMAGNETIC RELAY

5945-01-183-6335 A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.

Part Alternates: MS274005U, MS27400-5U, A05282, MILPRF6106, MIL-PRF-6106, MILR6106, MIL-R-6106, 5945-01-183-6335, 01-183-6335, 5945011836335, 011836335

Electrical and Electronic Equipment Components | Relays and Solenoids

Supply Group (FSG) NSN Assign. NIIN
59 07 JUL 1984 01-183-6335

Cross Reference | NSN 5945-01-183-6335

Part Number Cage Code Manufacturer
A05282 K0967 MBDA UK LTD
MIL-PRF-6106 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MIL-R-6106 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MS27400-5U 96906 MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5945-01-183-6335

Technical Data | NSN 5945-01-183-6335

Characteristic Specifications
NONPILE-UP MAIN CONTACT ARRANGEMENT 4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC AND 28.0 DC
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 10.0 AMPERES AC AND 10.0 AMPERES DC RESISTIVE LOAD 2.0 AMPERES AC AND 2.0 AMPERES DC LAMP LOAD 4.0 AMPERES AC AND 4.0 AMPERES DC MOTOR LOAD
COIL QUANTITY 1
WINDING QUANTITY 1
WINDING DC RESISTANCE RATING 290.0 OHMS NOMINAL SINGLE WINDING
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
NOMINAL OPERATING CURRENT RATING AND TYPE 120.0 MILLIAMPERES DC SINGLE WINDING
TERMINAL TYPE AND QUANTITY 14 WIRE HOOK ALL FUNCTIONS
TIME DELAY 0.015 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME
DUTY TYPE CONTINUOUS
ENVIRONMENTAL PROTECTION HERMETIC
OVERALL LENGTH 1.718 INCHES MAXIMUM
OVERALL WIDTH 1.025 INCHES MAXIMUM
OVERALL HEIGHT 1.320 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY 3 SLOTTED HOLE SINGLE MOUNTING FACILITY
MOUNTING FACILITY PATTERN TRIANGLE SINGLE MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 0.625 INCHES NOMINAL SINGLE MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE 1.396 INCHES MINIMUM AND 1.446 INCHES MAXIMUM SINGLE MOUNTING FACILITY
MOUNTING SLOT WIDTH 0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY
FEATURES PROVIDED POLARIZED
SPECIAL FEATURES FAILURE RATE LEVEL OF 0.5 PERCENT
TEST DATA DOCUMENT 81349-MIL-R-6106 SPECIFICATION
SPECIFICATION/STANDARD DATA 96906-MS27400 GOVERNMENT STANDARD
CRITICALITY CODE JUSTIFICATION FEAT
III CUBIC MEASURE 2.324 CUBIC INCHES
III UNPACKAGED UNIT WEIGHT 2.720 OUNCES
III FRAGILITY FACTOR MODERATELY RUGGED
III STORAGE TYPE GENERAL PURPOSE WAREHOUSE
III CASE MATERIAL METAL
MANUFACTURERS CODE 81349
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE MIL-PRF-6106
MANUFACTURERS CODE 96906
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE MS27400-5U

Restrictions/Controls & Freight Information | NSN 5945-01-183-6335

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:YThe item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code TH Defense Supply Center Columbus
Columbus, OH 43215
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5945-01-183-6335

Category Code Description
Cognizance Codes9NNavy-owned stocks of defense electronic material
Naval Inventory Control Point, Mechanicsburg
Source of SupplyS9EDefense Supply Center Columbus
Columbus, OH 43218
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative