Product Details | PULSE TRANSFORMER

5950-00-140-5688 A transformer designed to transfer pulses of nonsinusoidal wave forms between circuits without basically changing the wave forms.

Part Alternates: A1159, 20CL2G, 5950-00-140-5688, 00-140-5688, 5950001405688, 001405688

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 10 SEP 1971 00-140-5688

Cross Reference | NSN 5950-00-140-5688

Part Number Cage Code Manufacturer
20CL2G 27311 VIDCOR CO INC
A1159 27311 VIDCOR CO INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-140-5688

Technical Data | NSN 5950-00-140-5688

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 4 WIRE LEAD
DC RESISTANCE RATING IN OHMS 12.000 SINGLE COMPONENT SINGLE PRIMARY 13.000 SINGLE COMPONENT SINGLE SECONDARY
PRIMARY TO SECONDARY TURN RATIO 1 TO 1 SINGLE COMPONENT
(NON-CORE DATA) PULSE DURATION IN MICROSECONDS 16.500 SINGLE COMPONENT
(NON-CORE DATA) PULSE RISE TIME IN MICROSECONDS 0.020 SINGLE COMPONENT
PULSE REPETITION RATE 1.0 KILOHERTZ SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
MOUNTING METHOD TERMINAL SINGLE GROUP
INCLOSURE TYPE FULLY INCLOSED
BODY LENGTH 0.750 INCHES NOMINAL
BODY OUTSIDE DIAMETER 0.400 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED
MANUFACTURERS CODE 27311
DESIGN CONTROL REFERENCE A1159

Restrictions/Controls & Freight Information | NSN 5950-00-140-5688

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-00-140-5688

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesYTERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each