5950-00-494-8784 A transformer designed to transfer pulses of nonsinusoidal wave forms between circuits without basically changing the wave forms.

Part Alternates: 37000004, 37000-004, 5950-00-494-8784, 00-494-8784, 5950004948784, 004948784

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 13 JUN 1969 00-494-8784

Cross Reference | NSN 5950-00-494-8784

Part Number Cage Code Manufacturer
37000-004 52542 SYSTRON-DONNER CORP MICROWAVE/INSTRUMENT DIV

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-494-8784

Technical Data | NSN 5950-00-494-8784

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 4 WIRE LEAD
INDUCTANCE RATING 32.00 MILLIHENRIES NOMINAL SINGLE COMPONENT SINGLE PRIMARY 8.00 MILLIHENRIES NOMINAL SINGLE COMPONENT SINGLE SECONDARY
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
MOUNTING METHOD TERMINAL SINGLE GROUP
INCLOSURE TYPE FULLY INCLOSED
BODY LENGTH 0.750 INCHES NOMINAL
BODY OUTSIDE DIAMETER 0.688 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED
MANUFACTURERS CODE 52542
DESIGN CONTROL REFERENCE 37000-004

Restrictions/Controls & Freight Information | NSN 5950-00-494-8784

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code SG 403 SCMS/GUED
5215 Thurlow St, Suite 5, Bldg 70C
Wright-Patterson AFB OH 45433
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable