Product Details | PULSE TRANSFORMER

5950-00-686-1056 A transformer designed to transfer pulses of nonsinusoidal wave forms between circuits without basically changing the wave forms.

Part Alternates: PL139E, 5950-00-686-1056, 00-686-1056, 5950006861056, 006861056

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1961 00-686-1056

Cross Reference | NSN 5950-00-686-1056

Part Number Cage Code Manufacturer
PL139E 04386 MAGNETEK INC HUNTINGTON DIV
PL139E 0LG51 MAGNETEK INC LIGHTING PRODUCTS GROUP

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-686-1056

Technical Data | NSN 5950-00-686-1056

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 4 TAB, SOLDER LUG
DC RESISTANCE RATING IN OHMS 2.050 SINGLE COMPONENT SINGLE PRIMARY 2.300 SINGLE COMPONENT SINGLE SECONDARY
(NON-CORE DATA) PULSE DURATION IN MICROSECONDS 1.500 SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
MOUNTING METHOD THREADED STUD SINGLE GROUP
MOUNTING FACILITY QUANTITY 2 SINGLE GROUP
DISTANCE BETWEEN MOUNTING FACILITY CENTERS 0.562 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE FULLY INCLOSED
BODY LENGTH 1.125 INCHES NOMINAL
BODY HEIGHT 1.828 INCHES NOMINAL
BODY WIDTH 0.281 INCHES NOMINAL
SPECIAL FEATURES CASE METAL MATERIAL
MANUFACTURERS CODE 04386
DESIGN CONTROL REFERENCE PL139E

Restrictions/Controls & Freight Information | NSN 5950-00-686-1056

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating P 77.5
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable