Product Details | CURRENT TRANSFORMER

5950-00-712-7962 An item consisting of one or more windings, designed to be placed near or connected in series with an alternating current power line to measure the current passing through the line by means of a meter; or to control the current passing through the line by means of a control device. Excludes TRANSFORMER, POWER, CURRENT REGULATING.

Part Alternates: 3300A84B0193001, 3300A84B0193-001, 5950-00-712-7962, 00-712-7962, 5950007127962, 007127962

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1963 00-712-7962

Cross Reference | NSN 5950-00-712-7962

Part Number Cage Code Manufacturer
3300A84B0193-001 03538 LOCKHEED MARTIN CORPORATION DIV MST

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-712-7962

Technical Data | NSN 5950-00-712-7962

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 2 WIRE LEAD
MOUNTING METHOD SLOT SINGLE GROUP
MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
MOUNTING SLOT WIDTH 0.222 INCHES NOMINAL SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 3.773 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.610 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE FULLY INCLOSED
OVERALL LENGTH 5.269 INCHES NOMINAL
OVERALL HEIGHT 4.334 INCHES NOMINAL
OVERALL WIDTH 2.291 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED

Restrictions/Controls & Freight Information | NSN 5950-00-712-7962

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable