Product Details | CURRENT TRANSFORMER

5950-00-914-4721 An item consisting of one or more windings, designed to be placed near or connected in series with an alternating current power line to measure the current passing through the line by means of a meter; or to control the current passing through the line by means of a control device. Excludes TRANSFORMER, POWER, CURRENT REGULATING.

Part Alternates: ST30273, TP1514, 7284761, 7930688, 5950-00-914-4721, 00-914-4721, 5950009144721, 009144721

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1960 00-914-4721

Cross Reference | NSN 5950-00-914-4721

Part Number Cage Code Manufacturer
7284761 16758 GENERAL MOTORS CORP DELCO ELECTRONICS DIV
7284761 24617 GENERAL MOTORS CORP
7930688 98749 SACRAMENTO AIR LOGISTICS CENTER SM-ALC/LIIL
ST30273 97102 STERLING TRANSFORMER CORP
TP1514 91196 NORTH ERIE ELECTRONICS, INC DBA FISHER ENGINEERING

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-914-4721

Technical Data | NSN 5950-00-914-4721

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 4 TAB, SOLDER LUG
WINDING OPERATING VOLTAGE 7.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT 100.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY 50.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
FREQUENCY RATING 400.0 HERTZ MAXIMUM SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD FLANGE SINGLE GROUP
MOUNTING FACILITY QUANTITY 2 1ST GROUP
MOUNTING HOLE DIAMETER 0.152 INCHES NOMINAL SINGLE GROUP
DISTANCE BETWEEN MOUNTING FACILITY CENTERS 1.812 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE FULLY INCLOSED
BODY LENGTH 2.124 INCHES NOMINAL
BODY HEIGHT 0.875 INCHES NOMINAL
BODY WIDTH 1.500 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED
III INSTALLATION FOR WHICH DESIGNED INDOOR NONPORTABLE

Restrictions/Controls & Freight Information | NSN 5950-00-914-4721

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable