NSN 5950-01-019-3797 100689, 13678, 70183

Product Details | RADIO FREQUENCY COIL


5950-01-019-3797 An item consisting of a partial turn as one or more turns of wire or other conductive material which constitutes one continuous untapped winding. It may be wound or formed in other than a circular manner and may be self-supporting, requiring no coil form. It is specifically designed to furnish inductive reactance in a circuit carrying radio frequency current ranging from 20 kilohertz (kilocycles) and above. It may include tuning devices, integral resistors and capacitors; however, excludes FILTER (as modified). The coil has only two electrical terminals. For items having tapped winding or more than one winding - see TRANSFORMER, RADIO FREQUENCY. For coils wound on resistors, which are designed to be inserted in the circuit of a radio frequency stage to suppress high frequency parasitic oscillations, see SUPPRESSOR, PARASITIC.

Part Alternates: 100689, 13678, 70183, 92001283, 920012-83, 5950-01-019-3797, 01-019-3797, 5950010193797, 010193797

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 14 APR 1976 01-019-3797

Drawings & Photos | NSN 5950-01-019-3797




Cross Reference | NSN 5950-01-019-3797


Part Number Cage Code Manufacturer
100689 76493 BELL INDUSTRIES INC J W MILLER MAGNETICS DIV
13678 03550 VANGUARD ELECTRONICS COMPANY
70183 05254 AMI/COAST MAGNETICS INC. DBA COAST MAGNETICS
920012-83 82577 RAYTHEON COMPANY DBA RAYTHEON

Request a Quote



Comments | What our customers are saying...


Honeywell

Thank you very much for the excellent service and professional customer care.

Ernie G. Honeywell
Raytheon

The service was excellent. I can think of no improvements to date that you can make regarding internet sales.

John L. Raytheon
General Dynamics

The representative for WBParts was efficient & handled our request in a timely & professional manner.

Karen G. General Dynamics
US Airforce

Tried two other sources, neither of them responded, was all done online, never spoke to anyone.

Rex S. US Airforce
NASA

The response is quick and the price is often very good. We are completely satisfied.


NSNs for Compare ( up to 4 ): Add 5950-01-019-3797


Technical Data | NSN 5950-01-019-3797


Characteristic Specifications
TERMINAL TYPE AND QUANTITY 2 WIRE LEAD
RATING METHOD ELECTRICAL SINGLE COMPONENT SINGLE WINDING
WINDING OPERATING CURRENT 290.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING
DC RESISTANCE RATING IN OHMS 3.900 SINGLE COMPONENT SINGLE WINDING
INDUCTANCE RATING 39.00 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING
QUALITY FACTOR 80 MINIMUM SINGLE COMPONENT SINGLE WINDING
(NON-CORE DATA) FREQUENCY AT WHICH INDUCTANCE AND QUALITY FACTOR APPLIES 2.5 MEGAHERTZ SINGLE COMPONENT SINGLE WINDING
(NON-CORE DATA) MINIMUM SELF-RESONANT FREQUENCY 16.0 MEGAHERTZ SINGLE COMPONENT
COIL FORM TYPE SOLID SINGLE COMPONENT
MOUNTING METHOD TERMINAL SINGLE GROUP
INCLOSURE TYPE FULLY INCLOSED
BODY LENGTH 0.270 INCHES NOMINAL
BODY HEIGHT 0.330 INCHES MAXIMUM
BODY WIDTH 0.150 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED
III MAXIMUM OPERATING TEMP 125.0 DEG CELSIUS

Restrictions/Controls & Freight Information | NSN 5950-01-019-3797


Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-01-019-3797


Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each

Call us today at (321) 473-6075 or Email us at sales@wbparts.com

Supply Chain Solutions Beyond Expectations. Check out the many ways our site can help you. Start Here