NSN 5950-01-021-4630 C018570, C0-18570, RX00198
Product Details | PULSE TRANSFORMER
5950-01-021-4630 A transformer designed to transfer pulses of nonsinusoidal wave forms between circuits without basically changing the wave forms.
Part Alternates: C018570, C0-18570, RX00198, TP802, 402113, 5950-01-021-4630, 01-021-4630, 5950010214630, 010214630
Electrical and Electronic Equipment Components | Coils and Transformers
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 17 MAY 1976 | 01-021-4630 | 00208 ( TRANSFORMER, PULSE ) |
Demand History | NSN 5950-01-021-4630
| Part Number | Request Date | QTY | Origin |
|---|---|---|---|
| 5950-01-021-4630 | 2017-06-169 | 1 | DIBBS |
| 5950-01-021-4630 | 2016-12-349 | 1 | DIBBS |
| 5950-01-021-4630 | 2016-06-171 | 1 | DIBBS |
| 5950-01-021-4630 | 2016-03-61 | 4 | DIBBS |
| 5950-01-021-4630 | 2016-02-55 | 3 | DIBBS |
| 5950-01-021-4630 | 2015-06-181 | 9 | DIBBS |
| 5950-01-021-4630 | 2015-05-130 | 7 | DIBBS |
| 5950-01-021-4630 | 2014-10-295 | 5 | DIBBS |
| 5950-01-021-4630 | 2009-10-293 | 9 | DIBBS |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5950-01-021-4630
Related Products | NSN 5950-01-021-4630
Technical Data | NSN 5950-01-021-4630
| Characteristic | Specifications |
|---|---|
| TERMINAL TYPE AND QUANTITY | 2 CONNECTOR, RECEPTACLE AND 11 STANDOFF, THREADED STUD |
| (NON-CORE DATA) WINDING TAP LOCATION | MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT 3RD SECONDARY |
| WINDING OPERATING VOLTAGE | 7.60 AC VOLTS NOMINAL AND 10.20 AC VOLTS NOMINAL AND 11.20 AC VOLTS NOMINAL AND 12.60 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
| WINDING OPERATING CURRENT | 12.73 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY 2.3 AMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
| (NON-CORE DATA) PEAK VOLTAGE RATING | 18.7 KILOVOLTS SINGLE COMPONENT 1ST SECONDARY 18.0 KILOVOLTS SINGLE COMPONENT 2ND SECONDARY 4.2 KILOVOLTS SINGLE COMPONENT SINGLE PRIMARY |
| FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 3 SECONDARY AND 1 TERTIARY SINGLE COMPONENT |
| MOUNTING METHOD | FLANGE AND UNTHREADED HOLE SINGLE GROUP |
| MOUNTING FACILITY QUANTITY | 8 SINGLE GROUP |
| MOUNTING HOLE DIAMETER | 0.214 INCHES MINIMUM AND 0.224 INCHES MAXIMUM SINGLE GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.990 INCHES MINIMUM AND 3.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY 1ST CENTER GROUP 5.190 INCHES MINIMUM AND 5.210 INCHES MAXIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.990 INCHES MINIMUM AND 3.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| BODY LENGTH | 7.219 INCHES MINIMUM AND 7.281 INCHES MAXIMUM |
| BODY HEIGHT | 6.094 INCHES MINIMUM AND 6.156 INCHES MAXIMUM |
| BODY WIDTH | 7.219 INCHES MINIMUM AND 7.281 INCHES MAXIMUM |
| OVERALL HEIGHT | 11.031 INCHES MAXIMUM |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| III MAXIMUM OPERATING TEMP | 105.0 DEG CELSIUS |
Restrictions/Controls & Freight Information | NSN 5950-01-021-4630
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | U | Precious metal type is unknown |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 063420 | TRANSFORMERS,NOI,OR TRANSFORMER PAR |
| Less than car load rating | ||
| Less than truck load rating | W | Rating Variable |
| Water commodity Code | 595 | unknown |
| Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5950-01-021-4630
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |