Product Details | CURRENT TRANSFORMER

5950-01-123-4906 An item consisting of one or more windings, designed to be placed near or connected in series with an alternating current power line to measure the current passing through the line by means of a meter; or to control the current passing through the line by means of a control device. Excludes TRANSFORMER, POWER, CURRENT REGULATING.

Part Alternates: PEI 8881, PEI8881, 11424, 13090448, 3180809, 318-0809, 3199, 5950-01-123-4906, 01-123-4906, 5950011234906, 011234906

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 13 DEC 1981 01-123-4906

Cross Reference | NSN 5950-01-123-4906

Part Number Cage Code Manufacturer
11424 55196 SORA POWER INC. DBA SIGMA DIVISION
13090448 18876 U S ARMY AVIATION AND MISSILE COMMAND
318-0809 06978 VERNITRON CORP AIE MAGNETICS DIV
318-0809 09353 C AND K COMPONENTS INC
3199 05254 AMI/COAST MAGNETICS INC. DBA COAST MAGNETICS
PEI 8881 13483 PRECISION ELECTRONICS, INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-01-123-4906

Technical Data | NSN 5950-01-123-4906

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 11 PIN
(NON-CORE DATA) WINDING TAP LOCATION CENTER TAP SINGLE COMPONENT 2ND PRIMARY
WINDING OPERATING VOLTAGE 4.75 AC VOLTS MINIMUM AND 5.25 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST PRIMARY 0.10 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY 10.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY 1.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING CURRENT 0.2 AMPERES AC MAXIMUM SINGLE COMPONENT ALL SECONDARY
FREQUENCY RATING 10.0 KILOHERTZ NOMINAL SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 2 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD TERMINAL SINGLE GROUP
INCLOSURE TYPE FULLY INCLOSED
BODY LENGTH 1.200 INCHES MAXIMUM
BODY OUTSIDE DIAMETER 1.500 INCHES MAXIMUM
FEATURES PROVIDED TINNED WIRE LEADS
RELIABILITY INDICATOR NOT ESTABLISHED
III MAXIMUM OPERATING TEMP 105.0 DEG CELSIUS
(NON-CORE DATA) UNPACKAGED UNIT WEIGHT 3.500 OUNCES

Restrictions/Controls & Freight Information | NSN 5950-01-123-4906

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code BD U.S. Army Aviation and Missile Command
Redstone Arsenal, AL 35898-5230
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-01-123-4906

Category Code Description
Materiel Category and Inventory ManagerQ Electronics Materiel (DLA/GSA Items)
Appropriation and Budget Activity2 Stock Fund Secondary Items
Management Inventory Segment2 NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable.
Specific Group/Generic Code0 Medical Materiel
Weapons Systems/End Item or Homogeneous Group00DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item
Accounting Requirements CodeX Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDADepartment of the Army
Service OrganizationAU.S. Army
ReparabilityZThis is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item.
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each