NSN 5950-01-227-5353 5109054, 510-9054, 750X41G2
Product Details | CURRENT TRANSFORMER
5950-01-227-5353 An item consisting of one or more windings, designed to be placed near or connected in series with an alternating current power line to measure the current passing through the line by means of a meter; or to control the current passing through the line by means of a control device. Excludes TRANSFORMER, POWER, CURRENT REGULATING.
Part Alternates: 5109054, 510-9054, 750X41G2, 5950-01-227-5353, 01-227-5353, 5950012275353, 012275353
Electrical and Electronic Equipment Components | Coils and Transformers
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 05 MAR 1986 | 01-227-5353 | 00738 ( TRANSFORMER, CURRENT ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5950-01-227-5353
Related Products | NSN 5950-01-227-5353
Technical Data | NSN 5950-01-227-5353
| Characteristic | Specifications |
|---|---|
| WINDING OPERATING CURRENT | 15.0 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| MOUNTING METHOD | UNTHREADED HOLE 3RD GROUP |
| MOUNTING SLOT WIDTH | 0.438 INCHES NOMINAL 2ND GROUP |
| BODY LENGTH | 5.250 INCHES NOMINAL |
| MOUNTING METHOD | UNTHREADED HOLE 4TH GROUP |
| TERMINAL TYPE AND QUANTITY | 2 SCREW |
| MOUNTING FACILITY QUANTITY | 2 1ST GROUP |
| BODY HEIGHT | 6.310 INCHES NOMINAL |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.125 INCHES NOMINAL ALL MOUNTING FACILITIES SINGLE CENTER GROUP |
| SPECIAL FEATURES | PRIMARY RATED BUT NOT INCLUDED; 5TH MTG GROUP,4 UNTHD HOLES 0.313 IN. DIA |
| BODY WIDTH | 4.000 INCHES NOMINAL |
| WINDING FUNCTION AND QUANTITY | 1 SECONDARY SINGLE COMPONENT |
| OVERALL WIDTH | 13.000 INCHES NOMINAL |
| MOUNTING FACILITY QUANTITY | 2 3RD GROUP |
| MOUNTING FACILITY QUANTITY | 2 4TH GROUP |
| MOUNTING HOLE DIAMETER | 0.438 INCHES NOMINAL 3RD GROUP |
| MOUNTING METHOD | SLOT 1ST GROUP |
| MOUNTING METHOD | SLOT 2ND GROUP |
| MOUNTING HOLE DIAMETER | 0.563 INCHES NOMINAL 4TH GROUP |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 3.125 INCHES NOMINAL 2ND MOUNTING FACILITY 1ST CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.250 INCHES NOMINAL 2ND MOUNTING FACILITY SINGLE CENTER GROUP |
| MAXIMUM TRANSFORMER POWER RATING | 12.5 VOLT-AMPERE SINGLE COMPONENT |
| MOUNTING SLOT WIDTH | 0.563 INCHES NOMINAL 1ST GROUP |
| WINDING OPERATING CURRENT | 5.0 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 12.000 INCHES NOMINAL 2ND MOUNTING FACILITY 2ND CENTER GROUP |
| FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 9.250 INCHES NOMINAL 1ST MOUNTING FACILITY SINGLE CENTER GROUP |
| MOUNTING FACILITY QUANTITY | 4 2ND GROUP |
| INCLOSURE TYPE | FULLY INCLOSED |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.760 INCHES NOMINAL 1ST MOUNTING FACILITY SINGLE CENTER GROUP |
Restrictions/Controls & Freight Information | NSN 5950-01-227-5353
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 063420 | TRANSFORMERS,NOI,OR TRANSFORMER PAR |
| Less than car load rating | ||
| Less than truck load rating | W | Rating Variable |
| Water commodity Code | 595 | unknown |
| Originating Activity Code | TH | Defense Supply Center Columbus Columbus, OH 43215 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5950-01-227-5353
| Category | Code | Description |
|---|---|---|
| Budget Code | 9 | General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors. |
| Materiel Management Aggregation Code | EH | SX:ELECTRONIC COMPONENTS |
| Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
| Fund Code | SF | Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point. |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DF | Department of the Air Force |
| Service Organization | F | U.S. Air Force |
| Reparability | N | Stock Fund (except Munitions) |
| Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |



