Product Details | CURRENT TRANSFORMER

5950-01-242-2800 An item consisting of one or more windings, designed to be placed near or connected in series with an alternating current power line to measure the current passing through the line by means of a meter; or to control the current passing through the line by means of a control device. Excludes TRANSFORMER, POWER, CURRENT REGULATING.

Part Alternates: 110, 5950-01-242-2800, 01-242-2800, 5950012422800, 012422800

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 09 OCT 1986 01-242-2800

Demand History | NSN 5950-01-242-2800

Part Number Request Date QTY Origin
110 2019-08-242 1
110 2015-05-126 1

Cross Reference | NSN 5950-01-242-2800

Part Number Cage Code Manufacturer
110 15815 GEOTRONIC LABS INC DBA GEOTRONICS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-01-242-2800

Technical Data | NSN 5950-01-242-2800

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 1 CONNECTOR, RECEPTACLE
WINDING OPERATING CURRENT 65.0 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY 0.49 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
FREQUENCY RATING 1.0 HERTZ NOMINAL SINGLE COMPONENT
MAXIMUM TRANSFORMER POWER RATING 0.1 VOLT-AMPERE SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD UNTHREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY 1 SINGLE GROUP
MOUNTING HOLE DIAMETER 2.000 INCHES NOMINAL SINGLE GROUP
INCLOSURE TYPE FULLY INCLOSED
BODY LENGTH 4.375 INCHES NOMINAL
BODY HEIGHT 4.000 INCHES NOMINAL
BODY WIDTH 1.000 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED

Restrictions/Controls & Freight Information | NSN 5950-01-242-2800

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information