Product Details | CURRENT TRANSFORMER

5950-01-380-9845 An item consisting of one or more windings, designed to be placed near or connected in series with an alternating current power line to measure the current passing through the line by means of a meter; or to control the current passing through the line by means of a control device. Excludes TRANSFORMER, POWER, CURRENT REGULATING.

Part Alternates: 24-1097-000, 6621025010, 662-1025-010, 5950-01-380-9845, 01-380-9845, 5950013809845, 241097000, 013809845

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 04 OCT 1993 01-380-9845

Cross Reference | NSN 5950-01-380-9845

Part Number Cage Code Manufacturer
24-1097-000 11402 HISONIC, INC.
662-1025-010 13499 ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-01-380-9845

Technical Data | NSN 5950-01-380-9845

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 3 PIN
(NON-CORE DATA) WINDING TAP LOCATION CENTER TAP SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE 1.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
FREQUENCY RATING 100.0 KILOHERTZ NOMINAL SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD TERMINAL SINGLE GROUP
INCLOSURE TYPE FULLY INCLOSED
BODY LENGTH 0.600 INCHES NOMINAL
BODY HEIGHT 0.415 INCHES NOMINAL
BODY WIDTH 0.500 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED
SPECIAL FEATURES EXTENDED NON-CONDUCTIVE CENTER POST
III MAXIMUM OPERATING TEMP 125.0 DEG CELSIUS
III HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION MOISTURE RESISTANT AND VIBRATION RESISTANT

Restrictions/Controls & Freight Information | NSN 5950-01-380-9845

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code TH Defense Supply Center Columbus
Columbus, OH 43215
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-01-380-9845

Category Code Description
Stores Account Code1Marine Corps Stock Fund Account Item.
Combat Essentiality Code2Non-Critical Repair Part. Repair parts or major components whose failure in an end item will not render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency, and which do not fit the definition of Code 3 or 4 items.
Materiel Management CodeBAll CommoditiesDefense Logistics Agency, (DLA,)
Echelon Management Code2ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled.
Physical Category Code1Bin
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDMU.S. Marine Corps
Service OrganizationMU.S. Marine Corps
ReparabilityZNonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code.
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each