Product Details | CURRENT TRANSFORMER

5950-01-535-0976 An item consisting of one or more windings, designed to be placed near or connected in series with an alternating current power line to measure the current passing through the line by means of a meter; or to control the current passing through the line by means of a control device. Excludes TRANSFORMER, POWER, CURRENT REGULATING.

Part Alternates: 191101, 191-101, 321-7646494 ITEM NO.22, 3217646494ITEMNO22, 5950-01-535-0976, 01-535-0976, 5950015350976, 015350976

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 15 NOV 2005 01-535-0976

Demand History | NSN 5950-01-535-0976

Part Number Request Date QTY Origin
191-101 2021-01-06 2 DIBBS

Cross Reference | NSN 5950-01-535-0976

Part Number Cage Code Manufacturer
191-101 5Y543 FLEX-CORE DIV OF MORLAN AND ASSOCIATES INC
321-7646494 ITEM NO.22 53711 NAVAL SEA SYSTEMS COMMAND

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-01-535-0976

Technical Data | NSN 5950-01-535-0976

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 2 THREADED STUD
FREQUENCY RATING 25.0 HERTZ MINIMUM AND 400.0 HERTZ MAXIMUM SINGLE COMPONENT
MOUNTING METHOD UNTHREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY 2 SINGLE GROUP
MOUNTING HOLE DIAMETER 0.420 INCHES NOMINAL SINGLE GROUP
INCLOSURE TYPE FULLY INCLOSED
OVERALL LENGTH 4.500 INCHES NOMINAL
OVERALL HEIGHT 4.880 INCHES NOMINAL
III END ITEM IDENTIFICATION CT ENCLOSURE
III PART NAME ASSIGNED BY CONTROLLING AGENCY METERING CLASS CURRENT TRANSFORMER

Restrictions/Controls & Freight Information | NSN 5950-01-535-0976

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-01-535-0976

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative