Product Details | DIODE SEMICONDUCTOR DEVICE

5961-01-085-5888 A two electrode semiconductor device having an asymmetrical voltage - current characteristic. May or may not include mounting hardware and/or heatsink. Excludes LIGHT EMITTING DIODE and SEMICONDUCTOR DEVICE,PHOTO. For items containing material such as selenium and copper oxide, see RECIFIER, METALLIC.

Part Alternates: 1782406049, 1782406-049, 1N2387A4, 1N2387AR, 41400151006, 414-00151-006, 5961-01-085-5888, 01-085-5888, 5961010855888, 010855888

Electrical and Electronic Equipment Components | Semiconductor Devices and Associated Hardware

Supply Group (FSG) NSN Assign. NIIN
59 10 NOV 1979 01-085-5888

Cross Reference | NSN 5961-01-085-5888

Part Number Cage Code Manufacturer
1782406-049 07187 HONEYWELL INTERNATIONAL INC. DBA HONEYWELL
1N2387A4 12954 MICROSEMI CORP.-SCOTTSDALE DBA MICROSEMI
1N2387A4 59377 MICROSEMI CORP-COLORADO
1N2387AR 24444 GENERAL SEMICONDUCTOR INDUSTRIES INC
414-00151-006 F6151 SAFRAN
414-00151-006 F6158 SFIM INDUSTRIES
414-00151-006 FAQ15 SAGEM DEFENSE SECURITE - GROUPESAFRAN

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5961-01-085-5888

Technical Data | NSN 5961-01-085-5888

Characteristic Specifications
SEMICONDUCTOR MATERIAL SILICON
MAXIMUM OPERATING TEMP PER MEASUREMENT POINT 200.0 DEG CELSIUS AMBIENT AIR
INCLOSURE MATERIAL METAL
MOUNTING METHOD TERMINAL
TERMINAL LENGTH 1.000 INCHES MINIMUM AND 1.625 INCHES MAXIMUM
OVERALL LENGTH 0.293 INCHES MINIMUM AND 0.357 INCHES MAXIMUM
FUNCTION FOR WHICH DESIGNED ZENER DIODE

Restrictions/Controls & Freight Information | NSN 5961-01-085-5888

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information