Product Details | DIODE SEMICONDUCTOR DEVICE

5961-01-295-5479 A two electrode semiconductor device having an asymmetrical voltage - current characteristic. May or may not include mounting hardware and/or heatsink. Excludes LIGHT EMITTING DIODE and SEMICONDUCTOR DEVICE,PHOTO. For items containing material such as selenium and copper oxide, see RECIFIER, METALLIC.

Part Alternates: GZ64410B, LC7.5A, LC75A, 2040039030, 204-0039-030, 5961-01-295-5479, 01-295-5479, 5961012955479, 012955479

Electrical and Electronic Equipment Components | Semiconductor Devices and Associated Hardware

Supply Group (FSG) NSN Assign. NIIN
59 08 MAR 1989 01-295-5479

Cross Reference | NSN 5961-01-295-5479

Part Number Cage Code Manufacturer
204-0039-030 13499 ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS
GZ64410B 0U8A3 PROTEK DEVICES LP DBA PROTEK DEVICES
GZ64410B 24444 GENERAL SEMICONDUCTOR INDUSTRIES INC
LC7.5A 24444 GENERAL SEMICONDUCTOR INDUSTRIES INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5961-01-295-5479

Technical Data | NSN 5961-01-295-5479

Characteristic Specifications
SEMICONDUCTOR MATERIAL SILICON
VOLTAGE RATING IN VOLTS PER CHARACTERISTIC 7.5 NOMINAL REVERSE VOLTAGE, INSTANTANEOUS AND 8.33 MINIMUM BREAKDOWN VOLTAGE, DC AND 9.21 MAXIMUM BREAKDOWN VOLTAGE, DC
CURRENT RATING PER CHARACTERISTIC 10.00 MILLIAMPERES NOMINAL ON-STATE CURRENT, INSTANTANEOUS AND 250.00 MICROAMPERES MAXIMUM REVERSE CURRENT, INSTANTANEOUS AND 100.00 AMPERES MAXIMUM PEAK PULSE CURRENT
POWER RATING PER CHARACTERISTIC 1.0 WATTS MAXIMUM REVERSE POWER DISSIPATION, DC
MAXIMUM OPERATING TEMP PER MEASUREMENT POINT 175.0 DEG CELSIUS JUNCTION
INCLOSURE MATERIAL PLASTIC
JOINT ELECTRONIC DEVICE ENGINEERING COUNCIL/JEDEC/CASE OUTLINE DESIGNATION DO-13
MOUNTING METHOD TERMINAL
TERMINAL LENGTH 1.500 INCHES MINIMUM
TERMINAL TYPE AND QUANTITY 2 UNINSULATED WIRE LEAD
OVERALL LENGTH 0.315 INCHES MINIMUM AND 0.350 INCHES MAXIMUM
OVERALL DIAMETER 0.220 INCHES NOMINAL
FUNCTION FOR WHICH DESIGNED TRANSIENT SUPPRESSOR
FEATURES PROVIDED BURN IN
(NON-CORE DATA) SPECIFICATION/STANDARD DATA 95105-204-0039-030 MANUFACTURERS SPECIFICATION CONTROL

Restrictions/Controls & Freight Information | NSN 5961-01-295-5479

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:BESD sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063025 SEMICONDUCTORS/DEVICES NOI ETC
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 72D unknown
Originating Activity Code TH Defense Supply Center Columbus
Columbus, OH 43215
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo 3 Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

Management | NSN 5961-01-295-5479

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each