Product Details | PLATE INSULATOR

5970-01-191-4805 An insulator having flat surfaces, with or without holes, whose thickness does not exceed 25 percent of its length or width, whichever is smaller, and whose shape is other than round. Excludes INSULATOR (1), SPACER; INSULATOR (1), WASHER; MOUNTING PAD, ELECTRICAL-ELECTRONIC COMPONENT; PLATE, ELECTRICAL SHIELD; and TERMINAL BOARD.

Part Alternates: 746140020001, 7461400200-01, 5970-01-191-4805, 01-191-4805, 5970011914805, 011914805

Electrical and Electronic Equipment Components | Electrical Insulators and Insulating Materials

Supply Group (FSG) NSN Assign. NIIN
59 09 OCT 1984 01-191-4805

Drawings & Photos | NSN 5970-01-191-4805


Cross Reference | NSN 5970-01-191-4805

Part Number Cage Code Manufacturer
7461400200-01 86360 GE AVIATION SYSTEMS LLC DBA GE AVIATION DIV INFORMATION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5970-01-191-4805

Technical Data | NSN 5970-01-191-4805

Characteristic Specifications
STYLE DESIGNATOR K1 FLAT, RECTANGULAR
OVERALL LENGTH 0.650 INCHES NOMINAL
OVERALL HEIGHT 0.010 INCHES NOMINAL
OVERALL WIDTH 0.150 INCHES NOMINAL
MATERIAL AND LOCATION OVERALL PLASTIC,SILICONE ELASTOMER,501C5046-01-025,FAIRCHI LD INDUSTRIES INC OR OVERALL PLASTIC,SILICONE ELASTOMER,CHO-THERM-R 1671,CHOMERICS INC
SPECIAL FEATURES 125 MICROINCH FINISH SURFACE
MANUFACTURERS CODE 86360
DESIGN CONTROL REFERENCE 7461400200-01

Restrictions/Controls & Freight Information | NSN 5970-01-191-4805

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 103300 INSULATING MATERIAL NOI
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 72D unknown
Originating Activity Code CH Defense Supply Center Richmond
Richmond, VA 23297
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable