Product Details | SPECIAL PURPOSE ELECTRICAL INSULATION SLEEVING

5970-01-241-0524 A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.

Part Alternates: 222K1323S, 222K132-3S, 222S1323S, 222S132-3S, 5970-01-241-0524, 01-241-0524, 5970012410524, 012410524

Electrical and Electronic Equipment Components | Electrical Insulators and Insulating Materials

Supply Group (FSG) NSN Assign. NIIN
59 20 SEP 1986 01-241-0524

Drawings & Photos | NSN 5970-01-241-0524


Cross Reference | NSN 5970-01-241-0524

Part Number Cage Code Manufacturer
222K132-3S 06090 TYCO ELECTRONICS CORPORATION
222S132-3S 06090 TYCO ELECTRONICS CORPORATION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5970-01-241-0524

Technical Data | NSN 5970-01-241-0524

Characteristic Specifications
STYLE DESIGNATOR B3 BOOT-90 DEGREES
LARGE END WALL THICKNESS OF MAIN BODY 0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
SMALL END WALL THICKNESS OF MAIN BODY 0.040 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINES TO EDGE OF SMALL END 1.500 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
DISTANCE FROM CENTERLINE OF SMALL END TO EDGE OF LARGE END 0.790 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY SMALL END INSIDE DIAMETER 0.590 INCHES MINIMUM AS SUPPLIED 0.240 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY LARGE END INSIDE DIAMETER 0.940 INCHES MINIMUM AS SUPPLIED 0.560 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
DISTANCE FROM TOP OF SHOULDER TO SMALL END OF MAIN BODY 0.670 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
HEIGHT 1.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ANGLE BETWEEN LARGE END AND SMALL END CENTERLINES IN DEG 90.0 NOMINAL AFTER UNRESTRICTED RECOVERY
MATERIAL PLASTIC,POLYOLEFIN AND COPPER COMPOSITE,RT-1370,RAYCHEM INC
COLOR BLACK
FLEXIBILITY SEMIRIGID
TEMP RATING -55.0 DEG CELSIUS AND 150.0 DEG CELSIUS
MINIMUM TENSILE STRENGTH 1500 POUNDS PER SQUARE INCH
DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS ANY ACCEPTABLE
ENVIRONMENTAL PROTECTION FLAME RESISTANT
SPECIAL FEATURES LARGE END HAS LIP

Restrictions/Controls & Freight Information | NSN 5970-01-241-0524

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 103300 INSULATING MATERIAL NOI
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 72D unknown
Originating Activity Code CX Defense Supply Center Richmond
Richmond, VA 23297-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5970-01-241-0524

Category Code Description
Stores Account Code1Marine Corps Stock Fund Account Item.
Combat Essentiality Code7An item that has been reviewed and determined not to fit the definition of codes 0 thru 6. These items are not assigned a specific application within the Marine Corps.
Materiel Management CodeBAll CommoditiesDefense Logistics Agency, (DLA,)
Echelon Management Code2ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDMU.S. Marine Corps
Service OrganizationMU.S. Marine Corps
ReparabilityZNonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code.
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each