Product Details | RADIO FREQUENCY TRANSMISSION LINE SWITCH

5985-00-430-9662 An item specifically designed for mechanically or electronically positioning one or more radio frequency transmission line sections so as to couple it or them to other sections in a radio frequency transmission line system. The switching function may be operated by a manual actuator, an electromechanical actuator or by means of an arrangement of semiconductors and passive circuit devices. Excludes RELAY, (as modified).202593000005985000000

Part Alternates: 7530PMM, 7530-PMM, 5985-00-430-9662, 00-430-9662, 5985004309662, 004309662

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 08-MAY-74 00-430-9662

Demand History | NSN 5985-00-430-9662

Part Number Request Date QTY Origin
5985-00-430-9662 2012-10-286 1 DIBBS
5985-00-430-9662 2008-11-310 1 US

Cross Reference | NSN 5985-00-430-9662

Part Number Cage Code Manufacturer
7530-PMM 96341 COBHAM ELECTRONIC SYSTEMS INC. DBA COBHAM DEFENSE ELECTRONICS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5985-00-430-9662

Technical Data | NSN 5985-00-430-9662

Characteristic Specifications
RF MAXIMUM VOLTAGE RATING 350.0 VOLTS RMS
SWITCH TYPE NONTRANSFER
POLE QUANTITY 1
THROW QUANTITY 2
TERMINAL TYPE AND QUANTITY 3 RECEPTACLE, COAXIAL
CONNECTOR END DESIGN FEMALE
SWITCH OPERATION SEQUENCE BREAKS BEFORE MAKES
SWITCHING TIME 200.0 MILLISECONDS
BODY STYLE RECTANGULAR
OVERALL LENGTH 1.312 INCHES NOMINAL
OVERALL HEIGHT 2.625 INCHES NOMINAL
OVERALL WIDTH 0.500 INCHES NOMINAL
SPECIAL FEATURES ACTUATED BYTOGGLE
III OPERATING TEMP RANGE -55.0 TO 85.0 DEG CELSIUS

Restrictions/Controls & Freight Information | NSN 5985-00-430-9662

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information