NSN 5985-01-024-5581 CS18S14, CS-18S14, 01-024-5581
Product Details | RADIO FREQUENCY TRANSMISSION LINE SWITCH
5985-01-024-5581 An item specifically designed for mechanically or electronically positioning one or more radio frequency transmission line sections so as to couple it or them to other sections in a radio frequency transmission line system. The switching function may be operated by a manual actuator, an electromechanical actuator or by means of an arrangement of semiconductors and passive circuit devices. Excludes RELAY, (as modified).202593000005985000000
Part Alternates: CS18S14, CS-18S14, 5985-01-024-5581, 01-024-5581, 5985010245581, 010245581
Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 13 JUL 1976 | 01-024-5581 | 05298 ( SWITCH, RADIO FREQUENCY TRANSMISSION LINE ) |
Demand History | NSN 5985-01-024-5581
| Part Number | Request Date | QTY | Origin |
|---|---|---|---|
| 5985-01-024-5581 | 2013-05-140 | 4 | DIBBS |
| 5985-01-024-5581 | 2013-03-77 | 4 | DIBBS |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5985-01-024-5581
Related Products | NSN 5985-01-024-5581
Technical Data | NSN 5985-01-024-5581
| Characteristic | Specifications |
|---|---|
| FREQUENCY RATING | 0.0 GIGAHERTZ MINIMUM AND 4.0 GIGAHERTZ MAXIMUM 1ST FREQUENCY VOLTAGE STANDING WAVE RATIO 0.0 GIGAHERTZ MINIMUM AND 4.0 GIGAHERTZ MAXIMUM 1ST FREQUENCY INSERTION LOSS REFERENCE 4.0 GIGAHERTZ MINIMUM AND 8.0 GIGAHERTZ MAXIMUM 2ND FREQUENCY VOLTAGE STANDING WAVE RATIO 4.0 GIGAHERTZ MINIMUM AND 8.0 GIGAHERTZ MAXIMUM 2ND FREQUENCY INSERTION LOSS REFERENCE 8.0 GIGAHERTZ MINIMUM AND 12.0 GIGAHERTZ MAXIMUM 3RD FREQUENCY VOLTAGE STANDING WAVE RATIO 8.0 GIGAHERTZ MINIMUM AND 12.0 GIGAHERTZ MAXIMUM 3RD FREQUENCY INSERTION LOSS REFERENCE |
| ACTUATOR CURRENT TYPE AND RATING IN AMPS | 0.260 DC NOMINAL |
| ACTUATOR VOLTAGE IN VOLTS | 24.0 MINIMUM AND 30.0 MAXIMUM |
| SWITCH TYPE | NONTRANSFER |
| POLE QUANTITY | 1 |
| THROW QUANTITY | 4 |
| COUPLING POSITION QUANTITY | 5 |
| TERMINAL TYPE AND QUANTITY | 5 TURRET |
| COAXIAL CONNECTOR SERIES DESIGNATION | SMA |
| CONNECTOR END DESIGN | FEMALE |
| SWITCH OPERATION SEQUENCE | BREAKS BEFORE MAKES |
| SWITCHING TIME | 20.0 MILLISECONDS |
| SWITCH RETURN MECHANISM TYPE | FAIL-SAFE |
| OVERALL LENGTH | 2.590 INCHES NOMINAL |
| OVERALL DIAMETER | 2.500 INCHES NOMINAL |
| III OPERATING TEMP RANGE | -54.0 TO 85.0 DEG CELSIUS |
Restrictions/Controls & Freight Information | NSN 5985-01-024-5581
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | D | Munitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.) |
| Controlled Inventory Item Code: | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
| Precious Metals Indicator Code: | U | Precious metal type is unknown |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 061300 | CIRCUIT BREAKER/SWITCH NOI |
| Less than car load rating | ||
| Less than truck load rating | P | 77.5 |
| Water commodity Code | 723 | unknown |
| Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5985-01-024-5581
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
| Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |