Product Details | RADIO FREQUENCY TRANSMISSION LINE SWITCH

5985-01-293-4065 An item specifically designed for mechanically or electronically positioning one or more radio frequency transmission line sections so as to couple it or them to other sections in a radio frequency transmission line system. The switching function may be operated by a manual actuator, an electromechanical actuator or by means of an arrangement of semiconductors and passive circuit devices. Excludes RELAY, (as modified).202593000005985000000

Part Alternates: D3419E002, D3-419E002, 401480832A2, 401-480832A-2, 4312061, 431206-1, 909C9160030, 909C91600-30, 5985-01-293-4065, 01-293-4065, 5985012934065, 012934065

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 02 FEB 1989 01-293-4065

Demand History | NSN 5985-01-293-4065

Part Number Request Date QTY Origin
5985-01-293-4065 2022-05-136 25 US
5985-01-293-4065 2014-07-190 211 DIBBS
5985-01-293-4065 2014-03-65 188 DIBBS
5985-01-293-4065 2013-12-344 65 DIBBS
5985-01-293-4065 2013-10-304 74 DIBBS
5985-01-293-4065 2013-09-272 133 DIBBS
5985-01-293-4065 2013-06-156 53 DIBBS
5985-01-293-4065 2013-03-70 61 DIBBS
5985-01-293-4065 2011-11-311 143 DIBBS
5985-01-293-4065 2011-10-280 265 DIBBS
5985-01-293-4065 2011-09-246 175 DIBBS
5985-01-293-4065 2011-07-203 46 DIBBS
5985-01-293-4065 2011-02-40 85 DIBBS
5985-01-293-4065 2010-08-222 94 DIBBS
5985-01-293-4065 2008-11-310 232 DIBBS
5985-01-293-4065 2008-01-11 33 DIBBS
D3419E002 2007-03-89 50 us
D3419E002 2007-03-88 50 us

Cross Reference | NSN 5985-01-293-4065

Part Number Cage Code Manufacturer
401-480832A-2 00471 DOW-KEY MICROWAVE CORPORATION
431206-1 00752 EDO CORPORATION DIV EDO CORPORATION AP&T
909C91600-30 00471 DOW-KEY MICROWAVE CORPORATION
909C91600-30 50140 K&L MICROWAVE, INC.
909C91600-30 82152 L-3 COMMUNICATIONS CORPORATION DBA DATRON ADVANCED TECHNOLOGIES
D3-419E002 08719 DUCOMMUN LABARGE TECHNOLOGIES, INC DBA AMERICAN ELECTRONICS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5985-01-293-4065

Technical Data | NSN 5985-01-293-4065

Characteristic Specifications
FREQUENCY RATING 15.0 GIGAHERTZ MINIMUM AND 18.0 GIGAHERTZ MAXIMUM 1ST FREQUENCY RF POWER HANDLING 0.0 GIGAHERTZ MINIMUM AND 8.0 GIGAHERTZ MAXIMUM 1ST FREQUENCY VOLTAGE STANDING WAVE RATIO 0.0 GIGAHERTZ MINIMUM AND 11.5 GIGAHERTZ MAXIMUM 1ST FREQUENCY INSERTION LOSS REFERENCE 10.0 GIGAHERTZ MINIMUM AND 15.0 GIGAHERTZ MAXIMUM 2ND FREQUENCY RF POWER HANDLING 8.0 GIGAHERTZ MINIMUM AND 18.0 GIGAHERTZ MAXIMUM 2ND FREQUENCY VOLTAGE STANDING WAVE RATIO 11.5 GIGAHERTZ MINIMUM AND 12.4 GIGAHERTZ MAXIMUM 2ND FREQUENCY INSERTION LOSS REFERENCE 0.0 GIGAHERTZ MINIMUM AND 10.0 GIGAHERTZ MAXIMUM 3RD FREQUENCY RF POWER HANDLING 12.4 GIGAHERTZ MINIMUM AND 18.0 GIGAHERTZ MAXIMUM 3RD FREQUENCY INSERTION LOSS REFERENCE
ACTUATOR CURRENT TYPE AND RATING IN AMPS 0.12 DC MAXIMUM
ACTUATOR VOLTAGE IN VOLTS 30.0 MAXIMUM
RF MAXIMUM VOLTAGE RATING 350.0 VOLTS RMS
SWITCH TYPE NONTRANSFER
POLE QUANTITY 1
THROW QUANTITY 2
COUPLING POSITION QUANTITY 3
TERMINAL TYPE AND QUANTITY 8 SOLDER STUD
COAXIAL CONNECTOR SERIES DESIGNATION SMA
CONNECTOR END DESIGN FEMALE
SWITCH OPERATION SEQUENCE BREAKS BEFORE MAKES
SWITCHING TIME 20.0 MILLISECONDS
SWITCH RETURN MECHANISM TYPE LATCHING
OVERALL LENGTH 2.460 INCHES MAXIMUM
OVERALL HEIGHT 0.500 INCHES NOMINAL
OVERALL WIDTH 1.340 INCHES NOMINAL
III OPERATING TEMP RANGE -55.0 TO 95.0 DEG CELSIUS
III MAXIMUM OPERATING ALTITUDE RATING 50000.0 FEET
III PRECIOUS MATERIAL GOLD
III PRECIOUS MATERIAL AND LOCATION CONTACTS GOLD
III SUPPLEMENTARY FEATURES COIL VOLTAGE 20.0 MIN; SWITCHING TIME 20 MSEC AT 20 VDC; DRIVER VOLTAGE 4.5 TO 5.5 VDC; DRIVER CURRENT 70 MA MAX; CONTACT RATING .5 AMP MIN AT 30 VDC MAX

Restrictions/Controls & Freight Information | NSN 5985-01-293-4065

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:GItem contains gold
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 723 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5985-01-293-4065

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesDDoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each