Product Details | RADIO FREQUENCY TRANSMISSION LINE SWITCH

5985-01-364-2919 An item specifically designed for mechanically or electronically positioning one or more radio frequency transmission line sections so as to couple it or them to other sections in a radio frequency transmission line system. The switching function may be operated by a manual actuator, an electromechanical actuator or by means of an arrangement of semiconductors and passive circuit devices. Excludes RELAY, (as modified).202593000005985000000

Part Alternates: DA0735B1, DA0735-B1, G5042011, G504201-1, 5985-01-364-2919, 01-364-2919, 5985013642919, 013642919

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 16 SEP 1992 01-364-2919

Cross Reference | NSN 5985-01-364-2919

Part Number Cage Code Manufacturer
DA0735-B1 28983 DAICO INDUSTRIES, INC.
G504201-1 3B150 RAYTHEON TECHNICAL SERVICES COMPANY LLC
G504201-1 49956 RAYTHEON COMPANY DBA RAYTHEON

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5985-01-364-2919

Technical Data | NSN 5985-01-364-2919

Characteristic Specifications
FREQUENCY RATING 49.0 MEGAHERTZ MINIMUM AND 99.0 MEGAHERTZ MAXIMUM SINGLE FREQUENCY OPERATING
VOLTAGE STANDING WAVE RATIO 1.30 SINGLE
INSERTION LOSS IN DECIBELS 1.50 SINGLE
ACTUATOR OPERATING METHOD RELAY
ACTUATOR CURRENT TYPE AND RATING IN AMPS 0.001 DC MAXIMUM
SWITCH TYPE NONTRANSFER
POLE QUANTITY 1
THROW QUANTITY 1
COUPLING POSITION QUANTITY 2
TERMINAL TYPE AND QUANTITY 14 PIN
OVERALL LENGTH 1.050 INCHES MINIMUM AND 1.070 INCHES MAXIMUM
OVERALL WIDTH 0.200 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY 14 TERMINAL

Restrictions/Controls & Freight Information | NSN 5985-01-364-2919

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:BESD sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 723 unknown
Originating Activity Code TH Defense Supply Center Columbus
Columbus, OH 43215
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5985-01-364-2919

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each