NSN 5985-01-527-2898 G0032914, 9114, 01-527-2898
Product Details | RADIO FREQUENCY TRANSMISSION LINE SWITCH
5985-01-527-2898 An item specifically designed for mechanically or electronically positioning one or more radio frequency transmission line sections so as to couple it or them to other sections in a radio frequency transmission line system. The switching function may be operated by a manual actuator, an electromechanical actuator or by means of an arrangement of semiconductors and passive circuit devices. Excludes RELAY, (as modified).202593000005985000000
Part Alternates: G0032914, 9114, 5985-01-527-2898, 01-527-2898, 5985015272898, 015272898
Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 27 JAN 2005 | 01-527-2898 | 05298 ( SWITCH, RADIO FREQUENCY TRANSMISSION LINE ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5985-01-527-2898
Related Products | NSN 5985-01-527-2898
Technical Data | NSN 5985-01-527-2898
| Characteristic | Specifications |
|---|---|
| FREQUENCY RATING | 1.0 GIGAHERTZ MINIMUM AND 18.0 GIGAHERTZ MAXIMUM SINGLE FREQUENCY OPERATING |
| ACTUATOR VOLTAGE IN VOLTS | 5.0 NOMINAL |
| TERMINAL TYPE AND QUANTITY | 3 PLUG, COAXIAL |
| BODY STYLE | 53B RECTANGULAR |
| OVERALL LENGTH | 1.510 INCHES NOMINAL |
| OVERALL HEIGHT | 1.190 INCHES MAXIMUM |
| OVERALL WIDTH | 0.380 INCHES NOMINAL |
| SPECIAL FEATURES | OPERATING TEMP - MINUS 65 DEG C TO 125 DEG C |
| III END ITEM IDENTIFICATION | SKYFLASH FOREBODY TEST SET, GENERAL MICROWAVE CORPORATION |
Restrictions/Controls & Freight Information | NSN 5985-01-527-2898
| Category | Code | Description |
|---|---|---|
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | B | Munitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.) |
| Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| No Freight Information | ||