Product Details | VARIABLE ATTENUATOR

5985-01-534-3118 A device for reducing the strength of an alternating current signal either continuously or in steps, without causing appreciable signal distortion, by maintaining substantially constant output and/or input impedance match. Continuously variable resistive devices must consist of at least two sections or one section with at least two rotating contacts. The item must have an overall attenuation rating. Includes tandem mounted variable resistors designed to function as an attenuator but whose terminals are not connected. See also RESISTOR, VAIABLE (as modified).

Part Alternates: A6P69X1AA, A6P-69X-1AA, 5985-01-534-3118, 01-534-3118, 5985015343118, 015343118

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 17 OCT 2005 01-534-3118

Cross Reference | NSN 5985-01-534-3118

Part Number Cage Code Manufacturer
A6P-69X-1AA 056E0 G.T. MICROWAVE INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5985-01-534-3118

Technical Data | NSN 5985-01-534-3118

Characteristic Specifications
APPLICATION DESIGN TRANSMISSION LINE
FREQUENCY RANGE 2.000 GIGAHERTZ MINIMUM AND 18.000 GIGAHERTZ MAXIMUM
OVERALL ATTENUATION RANGE IN DECIBELS 0.0 TO 64.0
ATTENUATION VARIATION METHOD CONTINUOUS
SPECIAL FEATURES DIGITALLY CONTROLLED ANALOG; CENTER FREQUENCY LESS THAN OR EQUAL TO 12.4 GHZ; MULTIOCTAVE BANDWIDTH; SWITCHING SPEED 1.0 MICROSECOND

Restrictions/Controls & Freight Information | NSN 5985-01-534-3118

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information