Product Details | DELAY LINE

5999-00-295-3140 An item which provides a predetermined delay to an electrical pulse, while maintaining substantially the same waveform. The delay is obtained by means of a real or artificial transmission line or equivalent device. The equivalent device may be acoustic, distributive, lumped constant, magnetic solid state, or surface acoustical wave type. See also ATTENUATOR, (as modified); TRANSFORMER, (as modified); and OSCILLATOR, PULSE DELAY.

Part Alternates: M7055A, 3040609-001-103, 5999-00-295-3140, 00-295-3140, 3040609001103, 5999002953140, 002953140

Electrical and Electronic Equipment Components | Miscellaneous Electrical and Electronic Components

Supply Group (FSG) NSN Assign. NIIN
59 22 SEP 1973 00-295-3140

Cross Reference | NSN 5999-00-295-3140

Part Number Cage Code Manufacturer
3040609-001-103 99696 LOCKHEED MARTIN CORPORATION DIV LOCKHEED MARTIN SYSTEMS & GLOBAL
M7055A 11312 TELEDYNE WIRELESS, LLC DBA TELEDYNE MICROWAVE SOLUTIONS
M7055A 24022 TELEDYNE WIRELESS, LLC DBA TELEDYNE MICROWAVE SOLUTIONS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5999-00-295-3140

Technical Data | NSN 5999-00-295-3140

Characteristic Specifications
OPERATING TEMP RANGE -40.0 TO 100.0 DEG CELSIUS
DELAY TIME VARIATION PER DEG CELSIUS NOT RATED
INPUT IMPEDANCE RATING 50.000 OHMS
OUTPUT IMPEDANCE RATING 50.000 OHMS
VOLTAGE RATING 15.000 VOLTS MINIMUM AND 115.000 VOLTS MAXIMUM
PULSE RISE TIME RATING NOT RATED
FREQUENCY RATING 400.000 HERTZ NOMINAL
ADJUSTMENT DEVICE DRIVE TYPE SLOTTED SCREW
ADJUSTMENT DEVICE QUANTITY 1
TERMINAL TYPE AND QUANTITY 3 COAXIAL RECEPTACLE
MOUNTING FACILITY UNTHREADED HOLE
MOUNTING FACILITY QUANTITY 4
MANUFACTURERS CODE 99696
MFR SOURCE CONTROLLING REFERENCE 3040609-001-103

Restrictions/Controls & Freight Information | NSN 5999-00-295-3140

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating P 77.5
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TA Sacramento Air Logistics Center
McClellan AFB, CA 95652-5609
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code Z unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5999-00-295-3140

Category Code Description
Cognizance Codes7RAeronautical Depot Level Repairable Spares
Naval Inventory Control Point, Philadelphia
Special Material IDMF (Non-JSL Items) FIGHTERAIRCRAFT(F4)
Issue Repair, or RequisitionARRepairable item subject to centrally managed rework program at designated sites. Mandatory turn-in of item required except when initial issue or replacement of surveyed item is involved.
Special Material Content2 Electrostatic Discharge (ESD)/Electromagnetic (EM) Sensitive Item
Source of SupplyN32Naval Inventory Control Point
Philadelphia, PA 19111-5098
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
ReparabilityHDepot Level Reparable
Acquisition Advice CodesYTERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each