Product Details | DELAY LINE

5999-01-181-6762 An item which provides a predetermined delay to an electrical pulse, while maintaining substantially the same waveform. The delay is obtained by means of a real or artificial transmission line or equivalent device. The equivalent device may be acoustic, distributive, lumped constant, magnetic solid state, or surface acoustical wave type. See also ATTENUATOR, (as modified); TRANSFORMER, (as modified); and OSCILLATOR, PULSE DELAY.

Part Alternates: DTTLDM150, DTTLDM-150, 5999-01-181-6762, 01-181-6762, 5999011816762, 011816762

Electrical and Electronic Equipment Components | Miscellaneous Electrical and Electronic Components

Supply Group (FSG) NSN Assign. NIIN
59 01-181-6762

Drawings & Photos | NSN 5999-01-181-6762


Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5999-01-181-6762

Technical Data | NSN 5999-01-181-6762

Characteristic Specifications
SIGNAL DELAY METHOD INDUCTANCE
DELAY TIME VARIATION METHOD TAPPED
INDIVIDUAL SECTION QUANTITY 1
SECTION DELAY TIME 150.000 NANOSECONDS NOMINAL SINGLE SECTION
SEGMENT QUANTITY PER SECTION 10 SINGLE SECTION
SEGMENT DELAY TIME 15.000 NANOSECONDS NOMINAL SINGLE SECTION ALL SEGMENTS
OPERATING TEMP RANGE 0.0 TO 70.0 DEG CELSIUS
DELAY TIME VARIATION PER DEG CELSIUS NOT RATED
INPUT IMPEDANCE RATING NOT RATED
OUTPUT IMPEDANCE RATING NOT RATED
ATTENUATION IN DECIBELS NOT RATED
VOLTAGE RATING 5.000 VOLTS NOMINAL
PULSE RISE TIME RATING 4.0 NANOSECONDS
FREQUENCY RATING NOT RATED
FREQUENCY BANDWIDTH NOT RATED
BODY STYLE 1 RECTANGULAR
BODY LENGTH 1.600 INCHES NOMINAL
BODY WIDTH 0.400 INCHES MAXIMUM
BODY DEPTH 0.225 INCHES MINIMUM AND 0.240 INCHES MAXIMUM
MATERIAL AND LOCATION PLASTIC, DIALLYL PHTHALATE, MIL-M-14, TYPE SDG BODY
SURFACE TREATMENT AND LOCATION PLASTIC, EPOXY BODY
TERMINAL TYPE AND QUANTITY 12 PIN
MOUNTING FACILITY TERMINAL
MOUNTING FACILITY QUANTITY 12
III INCLOSURE TYPE HERMETICALLY SEALED

Restrictions/Controls & Freight Information | NSN 5999-01-181-6762

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Electro-static Discharge Susceptible:BESD sensitivity
Category Code Description
No Freight Information