Product Details | MAGNETIC CONTACTOR

6110-00-519-5339 An item consisting of contacts, a magnetic core, and a coil with or without inclosure which is used to repeatedly establish and break a circuit. The item does not provide overload protection and is not used in line to control any other electrical controls. Excludes RELAY, ELECTROMAGNETIC and STARTER, MOTOR.l circuit. Exludes RELAY, ELECTRO-MAGNETIC and STARTER, MOTOR.

Part Alternates: 8502AG2115VSA, 8502AG2-115VSA, 8502SAG12S120V, 8502-SAG12-S-120V, 8502SAG12V02S, 6110-00-519-5339, 00-519-5339, 6110005195339, 005195339

Electric Wire, and Power and Distribution Equipment | Electrical Control Equipment

Supply Group (FSG) NSN Assign. NIIN
61 16 AUG 1974 00-519-5339

Cross Reference | NSN 6110-00-519-5339

Part Number Cage Code Manufacturer
8502-SAG12-S-120V 56365 SCHNEIDER ELECTRIC USA, INC. DBA SCHNEIDER ELECTRIC
8502AG2-115VSA 56365 SCHNEIDER ELECTRIC USA, INC. DBA SCHNEIDER ELECTRIC
8502SAG12V02S 51918 SCHNEIDER ELECTRIC USA, INC.
8502SAG12V02S 56365 SCHNEIDER ELECTRIC USA, INC. DBA SCHNEIDER ELECTRIC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6110-00-519-5339

Technical Data | NSN 6110-00-519-5339

Characteristic Specifications
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN DESIGNED PER NEMA STD
SIZE DESIGNATOR 00
OPERATING VOLTAGE CHARACTERISTIC FULL
AC VOLTAGE RATING 600.0 VOLTS MAXIMUM
FREQUENCY RATING 50.0 HERTZ NOMINAL AND 60.0 HERTZ NOMINAL
PHASE THREE
HORSEPOWER RATING 1.5000 AND 2.000
CONTROL TYPE LOCAL OR REMOTE
ACTUATION METHOD MAGNETIC
ACTUATOR VOLTAGE 120.0 AC
FREQUENCY IN HERTZ 50.0 AND 60.0
CIRCUIT PROTECTION FUSE NOT PROVIDED
PERFORMANCE TYPE SEMIAUTOMATIC
DUTY CYCLE CONTINUOUS
AMBIENT TEMP NOT RATED
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION GENERAL PURPOSE-NEMA TYPE 1
INCLOSURE FEATURE ANY ACCEPTABLE
OVERALL WIDTH 4.812 INCHES NOMINAL
OVERALL LENGTH 7.250 INCHES NOMINAL
OVERALL HEIGHT 4.250 INCHES NOMINAL
MOUNTING CONFIGURATION THREE MTG HOLES,ONE HOLE CENTEREDAT TOP,TWO BOTTOM HOLES 5-13/16 IN. FROM CENTER TOCENTER WITH TOP HOLE 1-1/2 IN. FROM CENTER LINE OF BOTTOM HOLES
SWITCH FUNCTIONAL POSITIONS START AND STOP
ACCESSORY NOT INCLUDED
MANUFACTURERS CODE 56365
DESIGN CONTROL REFERENCE 8502SAG12V02S

Restrictions/Controls & Freight Information | NSN 6110-00-519-5339

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 590 unknown
Originating Activity Code CX Defense Supply Center Richmond
Richmond, VA 23297-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6110-00-519-5339

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Fund CodeLPItems initially authorized for local purchase.
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Materiel Management Aggregation CodeSXSX:AF SICA RESIDUAL MMAC-OC-ALC
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesLLOCAL PURCHASE # (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each